44 en | System Operation <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>iNotice!This test is available only if your system sends alarms and system information to a monitoringservice, and was programmed by the security installing company to permit communicatortests.NOTICE!!Warning!Reset upon termination of testTerminating the communicator test function (with the [*/Back] key) resets the communicatorand discards all unsent reports. When an off-normal condition occurs during a Communicatortest, the test automatically resets, clearing all reports, so the off-normal conditions are sentnormally.6.4.36.4.46.4.56.4.6Battery/NAC circuits testIf a power failure occurs, your control panel has a built-in battery that continues to power thesystem for several hours. The control panel automatically recharges the battery when power isrestored. In this test mode, the system operates the local NAC circuits and tests the batteryfor two seconds. The test results are shown at the end of the test, and are not reported to thecentral station. Pressing the [*/Back] key or the [#/Enter] key returns the display to standbymode, or the unit times out after three minutes.Activate ouputs testThis test turns a selected output on and off manually.Zone input level testThis test shows the status of a selected on-board point. The loop existing through the point isshown. Normal loops show 11 mA to 15 mA. Loops in alarm show over 25 mA, and loops introuble show less than 6 mA.Addressable point test (MUX test)This test allows activation of the special test mode for addressable (multiplex) devices. Thisapplies only if the optional D7039 Addressable Point Bus Expander module is installed. Whenthis test mode is selected, the system asks which bus to test, 1 or 2. Select 1 to test points 9to 128 and select 2 to test points 129 to 255. The system presents 5 options:1. List Devices: Shows the point numbers of all devices on the selected bus. Some devices(such as a dual point module) can use two or more points2. Show Holes: Lists locations on the bus that have no assigned device. This can help to findprogramming errors or identify an available address for a new device.3. Show Extras: The system scans the bus to identify devices that are present on the bus,but are not programmed into the system. Scanning the bus takes about 60 sec. Restoringthe bus after scanning also takes about 60 sec. The system cannot identify devices aboveAddress 128 on Bus 1, or below Address 129 on Bus 2. If you know that a device isconnected to the system but cannot find it, ensure that it is connected to the correct bus:9 to 128 for Bus 1, 129 to 255 for Bus 2.4. Show Missing: Lists devices programmed into the system but not present on the bus arelisted. Unless a device was programmed into the system (such as using MUX EDIT), it isnot considered missing.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!