11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

70 en | <strong>Control</strong> Panel Programming <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>Enter the description using the numeric, [Silence] and [History] keys, then press [#/Enter] tosave the description.8.4.2Point functionShortcut: 0-PROG, 4-PROG INPUTS, 2-POINT FUNCTIONThere are 16 point functions, each of which has programmable features for: configuration(fire, waterflow, and so on), local only operation, silencing, and loop response.iNotice!At default, points 9 to 255 are programmed as Function 10 which is set as <strong>Fire</strong>. Function 11 isset as Supervisory. Function 04 is set as Waterflow 16 second.The following window appears:POINT FUNC. (__)(01 - 16):_______Enter the function number you wish to program and press [#/Enter]. The following windowappears:PROG FUNCT0- CONFIGURE1- LOCAL ONLY2- (reserved)3- SILENCABLE4- LOOP RESPONS5- (reserved) NXT FCT PREV FCTEnter the function you wish to program.ConfigureShortcut: 0-PROG, 4-PROG INPUTS, 2-POINT FUNCTION– <strong>Fire</strong>: When activated, the point shows FIRE ALARM on control panel and keypads,activates selected output devices, and sends a <strong>Fire</strong> <strong>Alarm</strong> report (if programmed). <strong>Fire</strong>points are defaulted to a latch when first configured.– Waterflow: When activated, the point shows WATERFLOW ALARM on control panel andkeypads, activates selected output devices, and sends a Waterflow <strong>Alarm</strong> report (ifprogrammed). Waterflow points are defaulted to a non-verify characteristic when firstconfigured.– Supervisory: When activated, the point shows SUPERVISORY ALARM on control paneland keypads, and sends a Supervisory <strong>Alarm</strong> report (if programmed). Supervisory pointsare defaulted to a non-verify characteristic when first configured.– Reset: When activated, the point initiates a control panel-reset operation to clear alarmsand reset smoke detectors. Only points 1 to 8 can be configured as reset points.– Silence: When activated, the point initiates a control panel silence operation to turn offsounders if the control panel is configured to allow silencing. Only points 1 to 8 can beconfigured as silence points.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!