98 en | Specifications <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>9SpecificationsiNotice!When a local relay is programmed for trouble it is energized in the normal state. This causesthe common and normally-open terminals to be shorted when not in the trouble condition.ElectricalPower (Input):Power (Auxiliary):120 V 60 Hz or 220 V 50 Hz, 2.2 A24 VDC nominal, unfiltered, 1.0 APower (Initiating Circuit [Smoke]) 1 : 24 VDC nominal, filtered, 1.0 A.Power (Option Bus):Power (Notification Appliance Circuit[NAC]) 2 :Power (Optional Standby Batteries):12 VDC nominal, 500 mAEach NAC has 24 VDC nominal, unfilteredpower with up to 2.5 A capacity (but limitedby overall 4.0 A capacity)Two 12 V (in series), 7 Ah to 40 Ah1For compatible smoke detection devices, see also the FPD‐7024 Smoke DetectorCompatibility List.2For compatible NAC devices, see also the FPD‐7024 NAC Compatibility ListEnvironmentalTemperature (operating and storage):+32°F to +120°F (0°C to +49°C)Notification Appliance Circuits (NACs)Wiring:standard Class B, Style Y or Class A, Style Z as needed.Notification patterns: Configurable for steady, pulsing, California March, ANSI code 3,synchronized Wheelock, synchronized Gentex, and synchronizedSystem Sensor.RelaysLocal (on-board):Remote 1 :The main control panel includes Three Form “C” relays. The relaycontacts are rated at 5 A, 28 VDC. No over existing limiting isperformed on the contacts of these relays. The default selectionfor the relays is to indicate general alarm and general systemtrouble and supervisory. By using point or zone mapping, theycan be programmed to activate in a wide variety of conditions.Eight Form C relay outputs are provided by a D7035 RemoteRelay Module. The module connects to the FPD‐7024 through theoption bus. The outputs are fully programmable, exactly as thelocal relays are programmed. Each output operates independentlyof the other seven to provide complete flexibility. Communicationwith the D7035 is supervised.Contact Rating: 5 A at 28 VDCNumber of Modules: two units maximum.1For wiring requirements, see Option bus wiring requirements, 34.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!