<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 63This feature determines how long the smoke detector power is off after reset. No alarms areregistered by the system for 5 sec after power is returned.The display scrolls through the TIMERS options. Press [1] for Smoke Reset. The followingwindow appears:SMOKE RESET (__ )(1-16 SECS):_______Enter the time and press [#/Enter]. The existing setting is shown in parentheses on the firstline. After you have programmed the smoke reset, the previous window appears.AC fail delayShortcut: 0-PROG, 3-PROG SYSTEM, 2-TIMERSThis feature sets the number of hours the control panel waits after an AC failure beforesending an AC Failure report. A setting of DC causes the system to send a report when 25% ofthe battery capacity is used.The display scrolls through the TIMERS options. Press [2] for AC FAIL DELAY. The followingwindow appears:AC FAIL DELAY1 - WAIT FOR DC2 - ENTER TIMEThe wait for DC function causes the AC fail report to be sent when the battery is 25%depleted, based on the measured voltage of the battery. If you want to WAIT FOR DC (25percent of capacity), press [1]. The existing setting is displayed in parentheses on the firstline, either “DC”, or the number of hours selected. After you program the AC Fail Delay, theprevious window appears.To ENTER TIME press [2]. The following window appears:AC FAIL DLY (___)(00-24 HRS):_______** For acceptable programming selections for UL864 9 th edition Listed applications, seeProgramming features for UL864, 49.Enter the time and press [#/Enter]. The existing setting is shown in parentheses on the firstline. After you program the AC Fail Delay, the previous window appears.iNotice!When Wait For DC is the existing selection, the Enter Time menu displays DC as the time inhours.Auto silenceShortcut: 0-PROG, 3-PROG SYSTEM, 2-TIMERSThis feature silences the sounding of an alarm condition on selected NACs after a certainamount of time. When you use Auto Silence, pressing [0/Prog] disables the feature and theonly way to turn off an alarm is to manually silence it. Entering between 5 min and 99 minmeans that the alarm sounds for that much time before automatically silencing.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!