90 en | <strong>Control</strong> Panel Programming <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>PROGRAM MUX1- MUX EDIT2- MUX PROGRAM3- BUS TYPE4- AUTO PROGRAM8.9.1MUX EditShortcut: 0-PROG, 9-PROGRAM MUX, 1- MUX EDITTo add MUX devices to the system, use the MUX Edit option. Each device must have a uniqueaddress programmed using the address switches.The following window appears:DEVICE TYPE ( )0- NO DEVICE2- SINGLE INPUT3- I/O MODULE4- MUX SMOKE5- SMOKE W/FRZ6- DUAL INPUT7- OCTAL INPUTDescriptionModel0- NO DEVICE2- SINGLE INPUT D7044/M, D7045, FMM-7045, D7052(Class A)3- I/O MODULE D70534- MUX SMOKE D7050, D7050TH, D3435- SMOKE W/FRZ Not Used6- DUAL INPUT D7052(Class B)7- OCTAL INPUT D7042Press the number that corresponds with the device you are adding or press [0/Prog] if you areremoving a device. When the device type is selected, the following window appears:POINT NUMBER(009 - 255) 009Enter the address of the point being added, and press [#/Enter]. The device type windowappears again allowing additional devices to be added. Eight points are added at once whenthe D7042 is added to the control panel.8.9.2MUX ProgramShortcut: 0-PROG, 9-PROGRAM MUX, 2-MUX PROGRAMTo add MUX devices to the system simultaneously while programming an address into thedevice itself, use the MUX Program option. This programs a specified address into the device,and also sets the control panel to use the device.!Warning!Programming issues!The D7042 is programmed using switches and cannot be added using the MUX Program feature.Use MUX Edit instead.All devices must be removed from MUX bus A before programming by removing power fromthe system, disconnecting the wires to the field devices, and re-powering the system. Failureto disconnect devices results in all devices on loop A being programmed to the new address.All programming is performed on Bus A, including addresses 129 to 255 that can only beinstalled on Bus B for operation. Be sure to connect devices with addresses 129 to 255 toBus B, not to Bus A.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!