11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 95NEW DEVICE @ xxx2 – SINGLE INPUT3 – I/O MODULE4 – MUX SMOKE5 – SMOKE W/FRZ6 - DUAL INPUT7 - OCTAL INPUT0 – NO DEVICEUse this menu to define the device type. Press the number key that corresponds with thedevice type installed at the address. If a detected device should not be installed and should beleft inactive, press [0/Prog] to bypass the new device.!Warning!Device malfunction!Ensure that the correct device type is selected for each point. Incorrectly specified devicetypes can cause multiplex devices to malfunction or fail to operate.All inputs are configured to use Point Function 10 as they are added. Points added during autoprogramming are configured for the following operation:– Point Function 10 (<strong>Fire</strong> <strong>Alarm</strong>, Fast Response, Non-silenceable, Not Local-only)– Open Status = Trouble– Output Zone 9– <strong>Alarm</strong> Verify = NO– Latching = YESThe programming of input points can be changed when auto programming completes usingthe input-programming menu.When I/O modules are added during auto programming, the relay (second point) is configuredto activate on any alarm, non-silenceable (Zone 63). This can be changed when autoprogramming completes by using the output-programming menu.The FPD‐7024 performs some basic error checks when new devices are added. The followingerrors can be shown during the process of adding a device:ADDRESS ERROR #AT ADDRESS xxxIn the previous message, # is replaced by a code number and xxx is replaced by the affectedaddress that indicates the type of error.For code numbers and corresponding error message descriptions, see the following table:Code Error Description1 New point is under an existingpointThe new point is in the space required for anexisting multi-address device. This is checkedwhen auto programming first starts.2 Point overlaps existing point There are already devices configured at one ofthe addresses required for the new multi-pointdevice.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!