Commissioning55.1 General information for commissioningWARNINGSecure the drive unit to prevent it from being started up unintentionally.Attach a warning notice to the start switch.WARNINGRemove any oil spillage immediately with an oil-binding agent in compliance withenvironmental requirements.CAUTIONOn cylindrical-roller bearings in the input unit, undershooting the minimum radial force candamage bearings.Prolonged test runs when off-load must be kept to a minimum.5.2 Checking the oil level prior to commissioningCheck the oil level before commissioning and correct it if necessary, see Checking andchanging lubricants (Page 59).Gearboxes with long-term preservation are delivered with a full tank of oil. We recommend acomplete oil change if your unit is left in storage for more than 24 months, see Checking andchanging lubricants (Page 59).5.3 Fitting the <strong>gearbox</strong> ventilation5.3.1 Screwing in the vent filter or pressure breather valve without securing clipIn the case of <strong>gearbox</strong>es with housing ventilation, the necessary vent filter or pressurebreather valve without a securing clip is delivered separately. They must be replaced withthe appropriate vent plug before starting up the <strong>gearbox</strong>.BA 2010Operating Instructions, 05/2011 49