Operation6ATEX version <strong>gearbox</strong>esThe difference between the temperature of the housing and the ambienttemperature of max. +40 °C must not exceed 70 K.Using a suitable temperature sensor, measure the temperature at the lowest pointof the housing (oil sump) or at the mounting surface in the case of output units.Changes are an indication of possible incipient damage.CAUTIONIn the event of changes during operation, the drive unit must be switched off immediately.Use the fault table in the section titled "Faults, causes, and remedies" to determine thecause of the fault.Remedy faults or have faults remedied.CAUTIONOn cylindrical-roller bearings in the input unit, undershooting the minimum radial force candamage bearings.Prolonged test runs when off-load must be kept to a minimum.Check the <strong>gearbox</strong> during operation for:● Excessive operating temperature● Changes in gear noise● Possible oil leakage at the housing and shaft seals.BA 2010Operating Instructions, 05/2011 51