13.07.2015 Views

Assessment and Future Directions of Nonlinear Model Predictive ...

Assessment and Future Directions of Nonlinear Model Predictive ...

Assessment and Future Directions of Nonlinear Model Predictive ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

458 P. Kühl et al.Table 1. List <strong>of</strong> process parameters <strong>and</strong> initial valuesΩ min 0.011 m 2 p 1 0.200 l/mol d 0.155 mV min 0.124 l p 2 0.032 l/mol T R,0 293.15 KM A 0.130 kg/mol p 3 -21.375 α 0.1 W/KM B 0.074 kg/mol p 4 12706.0 K C p 1523.3 J/KM C 0.074 kg/mol E 0 80.479 kJ/mol V 1 0.8 lM D 0.130 kg/mol E 2 79.160 kJ/mol V 2 1.6 lM K1 0.098 kg/mol E 3 69.975 kJ/mol m A,0 0.00 gρ A 979.381 kg/m 3 E 4 76.617 kJ/mol m B,0 510.98 gρ B 772.288 kg/m 3 R 8.314 J/(mol K) m K1 ,0 5.01 gρ C 955.869 kg/m 3 c p,A 238.519 J/(mol K) U 1 195 W/(m 2 K)ρ D 830.422 kg/m 3 C p,I 89.859 J/K U 2 155 W/(m 2 K)A 0 5.362e7 l/(mol s) H 59458 J/mol m A 890.00 gA 2 2.807e10 l 2 /(mol 2 s) H dil 5070 J/mol t f 0.662 lA 3 3.948e10 l/(mol s) T J 293.65 K T a 298.85 KA 4 1.403e8 l/(mol s) T d 298.15 Kto be difficult because <strong>of</strong> typically appearing end constraints. In this case, endconstraints are avoided by observing that simply minimizing the amount <strong>of</strong> Bover time leads to a meaningful solution. The batch is stopped when the amount<strong>of</strong> B is below a desired threshold. The optimal control problem is formulated as:minu∫t f0n B (τ) 2 dτ (3)subject to (1), (2)0mol/s ≤ u(t) ≤ 0.004 mol/s∫ t ft 0=0u(τ) dτ =6.9 molT R (t) ≤ 333.15 KS(t) ≤ 363.15 K.The safety constraint S (defined in the next section) has to ensure that even inthe extreme case <strong>of</strong> a total cooling failure no runaway will occur. The prediction<strong>and</strong> control horizon <strong>of</strong> the NMPC controller are specified as 56 times the sampletime <strong>of</strong> t s = 50 s. With this choice, the horizon is slightly larger than theminimum batch time for this process. All states are assumed perfectly measured.3.1 A Suitable Safety Constraint to Avoid RunawaysIn the case <strong>of</strong> a cooling failure, the heat released during the reaction can nolonger be removed from the reactor. This leads to a temperature rise whichfurther accelerates the reactions. If enough reactant had accumulated before,

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!