Concentration of<br />
Organic Vapors<br />
(In the Breathing<br />
Zone)<br />
0 to 1 ppm total VOCs<br />
above background<br />
(using PID)<br />
1 ppm to 5 ppm total<br />
VOCs above<br />
background<br />
(using PID)<br />
0.5 ppm to 5 ppm of<br />
benzene<br />
(using Dräeger ® tube)<br />
5 – 100 ppm total<br />
VOCs above<br />
background<br />
(using PID)<br />
> 100 ppm total VOCs<br />
above background<br />
(using PID) or<br />
5 ppm benzene<br />
(by Dräeger ® tube)<br />
LAUSD Proposed South Region High School #9 & Middle School #4<br />
Table 10-1<br />
Action Levels for VOCs<br />
Level of<br />
Respiratory<br />
Protection<br />
10-3<br />
December 2006<br />
<strong>Site</strong> <strong>Specific</strong> <strong>Health</strong> & <strong>Safety</strong> <strong>Plan</strong> (<strong>HASP</strong>)<br />
Responses<br />
<strong>and</strong><br />
Air Monitoring Requirements<br />
Level D Stay upwind from the source/area of COC.<br />
Level D or C Stay upwind from the source/area of COC.<br />
Conduct benzene Dräeger ® tube monitoring to<br />
confirm the absence of this COCs. If presence of<br />
benzene is detected above 0.5 ppm, upgrade to<br />
Level C respiratory protection <strong>and</strong> follow<br />
responses described below (0.5 to 5 ppm of<br />
benzene [using Dräeger ® tube]). Maintain 15<br />
minute exposure > 2.5 ppm at all times.<br />
Level C Stay upwind from the source/area of COC.<br />
Conduct benzene Dräeger ® tube monitoring every<br />
15 minutes. Confirm its presence <strong>and</strong><br />
concentration using personal air sampling<br />
pumps/charcoal tube. At 5-ppm benzene on the<br />
Dräeger ® Level C<br />
tube, stop work <strong>and</strong> consult the PM.<br />
Stay upwind from source/area of COC; continue<br />
benzene Dräeger ® tube monitoring if the presence<br />
of this COC is found <strong>and</strong> conduct personal air<br />
sampling pumps/charcoal tube sampling to<br />
determine adequacy of respiratory protection.<br />
NA Stop work, evacuate the site, <strong>and</strong> consult the PM.<br />
When the total <strong>org</strong>anic vapor concentration exceeds 1 ppm above background for 30 seconds<br />
within the breathing zone, benzene colorimetric tube monitoring will begin. If benzene is<br />
detected above its action level, all requirements of Cal/OSHA Benzene St<strong>and</strong>ard, Title 8, CCR,<br />
Section 5218 will be implemented. All air readings will be collected in the breathing zone to<br />
determine the level of protection.<br />