Concentration of<br />

Organic Vapors<br />

(In the Breathing<br />

Zone)<br />

0 to 1 ppm total VOCs<br />

above background<br />

(using PID)<br />

1 ppm to 5 ppm total<br />

VOCs above<br />

background<br />

(using PID)<br />

0.5 ppm to 5 ppm of<br />

benzene<br />

(using Dräeger ® tube)<br />

5 – 100 ppm total<br />

VOCs above<br />

background<br />

(using PID)<br />

> 100 ppm total VOCs<br />

above background<br />

(using PID) or<br />

5 ppm benzene<br />

(by Dräeger ® tube)<br />

LAUSD Proposed South Region High School #9 & Middle School #4<br />

Table 10-1<br />

Action Levels for VOCs<br />

Level of<br />

Respiratory<br />

Protection<br />

10-3<br />

December 2006<br />

<strong>Site</strong> <strong>Specific</strong> <strong>Health</strong> & <strong>Safety</strong> <strong>Plan</strong> (<strong>HASP</strong>)<br />

Responses<br />

<strong>and</strong><br />

Air Monitoring Requirements<br />

Level D Stay upwind from the source/area of COC.<br />

Level D or C Stay upwind from the source/area of COC.<br />

Conduct benzene Dräeger ® tube monitoring to<br />

confirm the absence of this COCs. If presence of<br />

benzene is detected above 0.5 ppm, upgrade to<br />

Level C respiratory protection <strong>and</strong> follow<br />

responses described below (0.5 to 5 ppm of<br />

benzene [using Dräeger ® tube]). Maintain 15<br />

minute exposure > 2.5 ppm at all times.<br />

Level C Stay upwind from the source/area of COC.<br />

Conduct benzene Dräeger ® tube monitoring every<br />

15 minutes. Confirm its presence <strong>and</strong><br />

concentration using personal air sampling<br />

pumps/charcoal tube. At 5-ppm benzene on the<br />

Dräeger ® Level C<br />

tube, stop work <strong>and</strong> consult the PM.<br />

Stay upwind from source/area of COC; continue<br />

benzene Dräeger ® tube monitoring if the presence<br />

of this COC is found <strong>and</strong> conduct personal air<br />

sampling pumps/charcoal tube sampling to<br />

determine adequacy of respiratory protection.<br />

NA Stop work, evacuate the site, <strong>and</strong> consult the PM.<br />

When the total <strong>org</strong>anic vapor concentration exceeds 1 ppm above background for 30 seconds<br />

within the breathing zone, benzene colorimetric tube monitoring will begin. If benzene is<br />

detected above its action level, all requirements of Cal/OSHA Benzene St<strong>and</strong>ard, Title 8, CCR,<br />

Section 5218 will be implemented. All air readings will be collected in the breathing zone to<br />

determine the level of protection.<br />