METHOD OPTIMISATION<br />

Simonich et al. 2000; Bester 2004; Peck 2006). For determination <strong>of</strong> PBDEs the most<br />

frequently used injection systems are splitless <strong>and</strong> on-column injection (Covaci et al. 2003).<br />

Highly brominated PBDEs (octa- to decaBDE) are reported to be degraded during analytical<br />

process. Björklund et al. (2004) described the influence <strong>of</strong> GC settings on the determination<br />

<strong>of</strong> highly brominated PBDEs. If not selected properly, particularly column length <strong>and</strong><br />

injection technique may reduce the accuracy <strong>of</strong> the analytical method. Björklund et al. (2004)<br />

tested several inlets for the analysis <strong>of</strong> PBDEs. The authors concluded that the PTV inlet is<br />

the most suitable inlet for the analysis since the degradation <strong>of</strong> thermo-labile PBDEs is<br />

avoided.<br />

Due to the lack <strong>of</strong> functional groups which allows detection by other commonly applied<br />

detectors, all musk fragrances are routinely detected by m<strong>as</strong>s spectrometry (MS) (Yamagishi<br />

et al. 1981; Bester 2004; Peck et al. 2006; Lignell et al. 2008). Nitro musks have successfully<br />

been analysed with electron impact ionisation (EI) <strong>as</strong> the nitro groups give sufficient response<br />

(Rimkus 1999). In the EI mode <strong>of</strong> MS, usually three m<strong>as</strong>s fragments from the musk<br />

fragrances are produced <strong>as</strong> result <strong>of</strong> a cleavage between one or more methyl groups. So far,<br />

indications <strong>of</strong> co-elution <strong>of</strong> other substances within the m<strong>as</strong>s spectra were not observed<br />

(Bester 2009). However, musk fragrances <strong>of</strong>ten contain impurities (stereoisomers) which<br />

cannot be detected properly even if advanced technologies such <strong>as</strong> t<strong>and</strong>em MS or high<br />

resolution MS are applied (Bester 2009).<br />

Detection <strong>of</strong> PBDEs w<strong>as</strong> performed using MS either in the EI mode or the negative chemical<br />

ionisation mode (NCI) (Eljarrat 2003). M<strong>as</strong>s spectrometry in the EI mode produces a good<br />

selectivity through the formation <strong>of</strong> M + <strong>and</strong> the [M-2 Br] + which are used for identification<br />

<strong>and</strong> quantification. However, EI mode h<strong>as</strong> a low sensitivity for higher brominated congeners,<br />

such <strong>as</strong> penta-, octa-, <strong>and</strong> decaBDE <strong>and</strong> is therefore not routinely applied (Covaci et al. 2003).<br />

Benefit <strong>of</strong> the NCI mode is the enhanced sensitivity towards the Br - ions (m<strong>as</strong>s-to-chargeratio,<br />

m/z= 79, 81) <strong>and</strong> is therefore widely applied to detect PBDEs. However, the<br />

quantification with compound-specific m<strong>as</strong>s-labelled st<strong>and</strong>ards is not possible, since they<br />

exhibit the same m<strong>as</strong>s signal. In trace analysis it is strongly suggested to apply m<strong>as</strong>s-labelled<br />

st<strong>and</strong>ards for quantification. Furthermore, due to the low selectivity using two bromine ions,<br />

coelutions <strong>of</strong> other brominated compounds such <strong>as</strong> polybrominated biphenyls <strong>and</strong> MeO-<br />

PBDEs were reported (Stapleton 2006).<br />

For the quantification <strong>of</strong> musk fragrances only two m<strong>as</strong>s-labelled internal st<strong>and</strong>ards (IS) are<br />