<strong>Legacy</strong> <strong>Data</strong><br />
12.7 R-ASYNC Port<br />
12.7.1 Reception flow control<br />
For R-ASYNC and asynchronous PPP protocols only.<br />
Flow control on the receiver. This parameter defines the method used by the NetPerformer<br />
to control the flow of data received from the attached equipment. Flow control is applied<br />
when the number of characters on input exceeds a predefined threshold.<br />
12.7.2 Transmission flow control<br />
For R-ASYNC and asynchronous PPP protocols only.<br />
Flow control on the transmitter. This parameter defines the method used by the attached<br />
equipment to control the flow of data transmitted by the NetPerformer.<br />
12.7.3 Transmit holding time (s)<br />
Console SNMP Text-based Config<br />
Reception flow control ifwanRxFlow [ifwan#] RxFlow<br />
Values: NONE, XON_XOFF<br />
Default: NONE<br />
Console SNMP Text-based Config<br />
Transmission flow control ifwanTxFlow [ifwan#] TxFlow<br />
Values: NONE, XON_XOFF<br />
Default: NONE<br />
Console SNMP Text-based Config<br />
Transmit holding time (s) ifwanTxHold-s [ifwan#] TxHold-s<br />
For R-ASYNC and asynchronous PPP protocols only.<br />
Hold time on the transmitter. This parameter defines the maximum time, in seconds, that<br />
the transmitter can be blocked due to flow control. There is no hold time limit if this<br />
parameter is configured as 0 seconds.<br />
Values: 0 - 2000<br />
Default: 0<br />