13.1.11 SDLC transmission window size<br />
13.1.12 XID support<br />
Console SNMP Text-based Config<br />
SDLC transmission window<br />
size<br />
puSdlcWindow [pu#] SdlcWindow<br />
For all PU modes with an SDLC connection.<br />
Transmission window size.<br />
Values: 1 - 7<br />
Default: 7<br />
Console SNMP Text-based Config<br />
XID support puXid [pu#] Xid<br />
For SDLC-SDLC and SDLC-LINKS modes only.<br />
PU exchanges identification. This parameter determines whether the PU expects to<br />
exchange PU identification with the device it is connected to, and ensures the identity of<br />
the remote PU in SNA applications. Set to NO if the PU does not support XID.<br />
Values: NO, YES<br />
Default: YES<br />
13.1.13 Suppress DM upon disconnection<br />
Console SNMP Text-based Config<br />
Suppress DM upon disconnection<br />
puSuppdDmDisc [pu#] SuppdDmDisc<br />
For PUs associated with secondary SDLC (S-SDLC) ports.<br />
This parameter controls the transmission of a Disconnect Message (DM) frame. A DM is a<br />
Disconnect Message sent from the secondary station (controller) to the primary station<br />
(host). It tells the primary that the secondary is in disconnect mode.<br />
When set to YES, a DM frame is suppressed rather than transmitted. This prevents the S-<br />
SDLC PU from replying to a frame from the primary PU with a DM frame. This setting<br />
may be useful for a PU4-to-PU4 connection when the configuration is downloaded using<br />
SIM (Set Initialize Mode) messages.<br />
When set to NO, the PU processes Disconnect Messages like a regular SDLC PU.<br />
Values: NO, YES<br />
Default: NO<br />