12.9 COP Port<br />
12.9.1 Synchronization character<br />
SE/PORT Configuration Parameters<br />
For COP protocol only.<br />
The hexadecimal value of the synchronization character. The Synchronization Character<br />
must be different from the Idle that has been defined for the COP port, or synchronization<br />
cannot be achieved. For example, if the Synchronization Character is 0000 then the Idle<br />
parameter cannot be set to SPACE. If the Synchronization Character is set to FFFF, then<br />
the Idle must be set to SPACE to get the port working. The following table summarizes<br />
these requirements:<br />
12.9.2 Number of desynch. character<br />
s<br />
For COP protocol only.<br />
This parameter defines the number of contiguous desynchronization characters that must<br />
be received before the NetPerformer drops synchronization and closes the frame.<br />
12.9.3 Desynchronization character<br />
Console SNMP Text-based Config<br />
Synchronization character<br />
Idle Synchronization Character<br />
SPACE Any value different from 0000<br />
MARK Any value different from FFFF<br />
Values: 0000 - FFFF<br />
Default: 1616<br />
ifwanSync [ifwan#] Sync<br />
Console SNMP Text-based Config<br />
Number of desynch.<br />
characters<br />
Values: 1 - 100<br />
Default: 3<br />
ifwanDropSyncCoun-ter ifwan#]<br />
DropSyncCounter<br />
Console SNMP Text-based Config<br />
Desynchronization character<br />
ifwanDropSyncCharacter ifwan#] Drop- SyncCharacter<br />
For COP protocol only.<br />
The hexadecimal value of the desynchronization character. This parameter defines the<br />