Legacy Data System Reference - Comtech EF Data
Legacy Data System Reference - Comtech EF Data
Legacy Data System Reference - Comtech EF Data
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Legacy</strong> <strong>Data</strong><br />
13.2.4 Remote unit<br />
13.2.5 Class<br />
13.2.6 Remote PU number<br />
Values: 128, 256, 512, 1024, 2048, 4096, 8192<br />
Default: 512<br />
The remaining parameters for configuring a PU in SDLC-LINKS mode affect the LINKS<br />
side of the connection:<br />
Console SNMP Text-based Config<br />
Remote unit puLinkRemoteUnit [pu#] LinkRemoteUnit<br />
For all PU modes with a LINKS connection.<br />
Remote unit to which data from this PU should be directed. The unit name is defined on<br />
the remote unit using the Setup Global menu. A unit name must be defined for each<br />
NetPerformer that will be participating in the network. Refer to the chapter Global<br />
Functions in the Quick Configuration module of this document series.<br />
Values: Maximum 16-character string, determined by remote NetPerformer<br />
setup<br />
Default: none<br />
Console SNMP Text-based Config<br />
Class puLinkClassNumber [pu#] ClassNumber<br />
For all PU modes with a LINKS connection.<br />
The priority class for data from this PU. Classes are defined according to bandwidth<br />
weight. For details, refer to the Quality of Service (QoS) module of this document<br />
series.<br />
Values: 1 - 8, HIGH PRIORITY<br />
Default: 2<br />
Console SNMP Text-based Config<br />
Remote PU number puLinkRemPu [pu#] LinkRemPu<br />
For all PU modes with a LINKS connection.<br />
The remote PU to which data from the local PU is sent. Specify the remote PU number.<br />
Values: 1 - 64<br />
Default: the local PU number<br />
13-8 Memotec Inc.