Legacy Data System Reference - Comtech EF Data
Legacy Data System Reference - Comtech EF Data
Legacy Data System Reference - Comtech EF Data
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Legacy</strong> <strong>Data</strong><br />
2.1 NetPerformer Support of HDLCOFR<br />
HDLC over Frame Relay (HDLCOFR), can be defined on a serial port or digital channel<br />
for data transport over Frame Relay. It is used for a multicast application of HDLC traffic:<br />
• An HDLC frame is received at the HDLCOFR port<br />
• The NetPerformer encapsulates the HDLC frame in a Frame Relay frame structure<br />
• The encapsulated frame is then sent out to a device capable of doing Frame Relay<br />
multicast transmissions<br />
• As a result, several remote stations can receive the same data.<br />
2.2 Configuring an HDLCOFR Connection<br />
SE/PORT/#/<br />
HDLCOFR<br />
example<br />
To configure a port or channel for HDLC over Frame Relay, set the Protocol parameter to<br />
HDLCOFR.<br />
SDM-9230>SE<br />
SETUP<br />
Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />
PHONE/<br />
PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />
def:BRIDGE) ? PORT<br />
Port number (ETH1/ETH2/CSL/1,def:1) ?<br />
PORT 1> Protocol (def:HDLC) ? HDLCOFR<br />
PORT 1> Interface...............................DCE-V35<br />
PORT 1> Clocking mode (def:INTERNAL) ?<br />
PORT 1> Port speed (bps) (1200-6144000,def:56000) ?<br />
PORT 1> Fallback speed (def:ENABLE) ?<br />
PORT 1> Tx/Rx mode (def:FULL) ?<br />
PORT 1> CRC encoding (def:NRZ) ?<br />
PORT 1> Idle (def:FLAG) ?<br />
PORT 1> PVC number (1-300,def:1) ?<br />
• Protocol, Interface, Clocking mode, Port speed (bps), Fallback speed, CRC<br />
encoding and Idle are common to HDLC ports, and are detailed in “SE/PORT<br />
Configuration Parameters” on page 12-1.<br />
Caution: The Dual Serial interface card for the SDM-9360, SDM-<br />
9380 and SDM-9585 does not support Fallback.<br />
• The other parameters are specific to defining an HDLCOFR port. Refer to the<br />
section “HDLCOFR Port” on page 12-13.<br />
2-2 Memotec Inc.