<strong>Legacy</strong> <strong>Data</strong><br />
SE/SLOT/<br />
Channel/T-<br />
ASYNC<br />
example<br />
5.4.2 R-ASYNC Connection<br />
PORT 1> Remote unit (def:) ? CHICAGO-9230<br />
PORT 1> Class (def:3) ?<br />
PORT 1> Remote port number (1-65534,def:1) ?<br />
• Protocol, Interface, Clocking mode, Port speed (bps), Modem control signal,<br />
Remote unit, Class and Remote port number are common to other legacy data<br />
port protocols. For details, go to “SE/PORT Configuration Parameters” on<br />
page 12-1.<br />
• The Format parameter is unique to the asynchronous protocols, and is detailed in<br />
the section “T-ASYNC Port” on page 12-15.<br />
SDM-9230>SE<br />
SETUP<br />
Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />
PHONE/<br />
PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />
def:BRIDGE) ? SLOT<br />
SLOT> Slot number (1/2/3,def:2) ?<br />
SLOT> Channel Number (201-202/ALL,def:201) ? 202<br />
PORT 202> Protocol (def:R-ASYNC) ? T-ASYNC<br />
PORT 202> Interface.............................DTE-V35<br />
PORT 202> Clocking mode (def:ASYNC) ?<br />
PORT 202> Port speed (bps) (300-115200,def:56000) ?<br />
PORT 202> Format (def:8-NONE) ?<br />
PORT 202> Modem control signal (def:STATIC) ?<br />
PORT 202> Remote unit (def:) ?<br />
PORT 202> Class (def:3) ?<br />
PORT 202> Remote port number (1-65534,def:202) ?<br />
• These are the same parameters as for T-ASYNC on a built-in serial port.<br />
The PORT or SLOT submenu of the SETUP console command includes all parameters<br />
required to configure an R-ASYNC port.<br />
If you are using SNMP, the required configuration variables are grouped under the ifwan<br />
category. For text-based configuration the [ifwan#] heading is used, where # represents<br />
the number of the port or channel.<br />
Console SNMP Text-based Config<br />
SE/PORT (serial port)<br />
SE/SLOT (digital channel<br />
or dual serial port)<br />
ifwan (category) [ifwan#] (heading)<br />
An R-ASYNC port can be configured on a built-in serial port or a serial port on a Dual<br />
Serial Port interface card.<br />
• To configure a built-in serial port on the base unit as an R-ASYNC port:<br />
5-4 Memotec Inc.