<strong>Legacy</strong> <strong>Data</strong><br />

SE/SLOT/<br />

Channel/T-<br />

ASYNC<br />

example<br />

5.4.2 R-ASYNC Connection<br />

PORT 1> Remote unit (def:) ? CHICAGO-9230<br />

PORT 1> Class (def:3) ?<br />

PORT 1> Remote port number (1-65534,def:1) ?<br />

• Protocol, Interface, Clocking mode, Port speed (bps), Modem control signal,<br />

Remote unit, Class and Remote port number are common to other legacy data<br />

port protocols. For details, go to “SE/PORT Configuration Parameters” on<br />

page 12-1.<br />

• The Format parameter is unique to the asynchronous protocols, and is detailed in<br />

the section “T-ASYNC Port” on page 12-15.<br />

SDM-9230>SE<br />

SETUP<br />

Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />

PHONE/<br />

PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />

def:BRIDGE) ? SLOT<br />

SLOT> Slot number (1/2/3,def:2) ?<br />

SLOT> Channel Number (201-202/ALL,def:201) ? 202<br />

PORT 202> Protocol (def:R-ASYNC) ? T-ASYNC<br />

PORT 202> Interface.............................DTE-V35<br />

PORT 202> Clocking mode (def:ASYNC) ?<br />

PORT 202> Port speed (bps) (300-115200,def:56000) ?<br />

PORT 202> Format (def:8-NONE) ?<br />

PORT 202> Modem control signal (def:STATIC) ?<br />

PORT 202> Remote unit (def:) ?<br />

PORT 202> Class (def:3) ?<br />

PORT 202> Remote port number (1-65534,def:202) ?<br />

• These are the same parameters as for T-ASYNC on a built-in serial port.<br />

The PORT or SLOT submenu of the SETUP console command includes all parameters<br />

required to configure an R-ASYNC port.<br />

If you are using SNMP, the required configuration variables are grouped under the ifwan<br />

category. For text-based configuration the [ifwan#] heading is used, where # represents<br />

the number of the port or channel.<br />

Console SNMP Text-based Config<br />

SE/PORT (serial port)<br />

SE/SLOT (digital channel<br />

or dual serial port)<br />

ifwan (category) [ifwan#] (heading)<br />

An R-ASYNC port can be configured on a built-in serial port or a serial port on a Dual<br />

Serial Port interface card.<br />

• To configure a built-in serial port on the base unit as an R-ASYNC port:<br />