<strong>Legacy</strong> <strong>Data</strong><br />

PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />

def:BRIDGE) ? PORT<br />

Port number (ETH1/ETH2/CSL/1,def:CSL) ? 1<br />

PORT 1> Protocol (def:PVCR) ? BSC<br />

PORT 1> Interface...............................DCE-V35<br />

PORT 1> Clocking mode (def:INTERNAL) ?<br />

PORT 1> Port speed (bps) (1200-64000,def:56000) ?<br />

PORT 1> Fallback speed (def:ENABLE) ?<br />

PORT 1> Modem control signal (def:STATIC) ?<br />

PORT 1> Transmission start level (def:AUTO) ?<br />

PORT 1> Remote unit (def:) ? CHICAGO-9230<br />

PORT 1> Class (def:3) ?<br />

PORT 1> Remote port number (1-65534,def:1) ?<br />

• All of these parameters are common to other legacy protocols, and are detailed in<br />

“SE/PORT Configuration Parameters” on page 12-1.<br />

7.3.2 BSC on the Dual Serial Interface Card<br />

SE/SLOT/<br />

Channel/BSC<br />

example<br />

When you define a serial port on a Dual Serial interface card with the BSC protocol, the<br />

following parameters are listed on the console:<br />

SDM-9230>SE<br />

SETUP<br />

Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />

PHONE/<br />

PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />

def:BRIDGE) ? SLOT<br />

SLOT> Slot number (1/2/3,def:2) ?<br />

SLOT> Channel Number (201-202/ALL,def:201) ?<br />

PORT 201> Protocol (def:OFF) ? BSC<br />

PORT 201> Interface.............................DCE-V35<br />

PORT 201> Clocking mode (def:INTERNAL) ?<br />

PORT 201> Port speed (bps) (1200-64000,def:56000) ?<br />

PORT 201> Fallback speed (def:ENABLE) ?<br />

PORT 201> Modem control signal (def:STATIC) ?<br />

PORT 201> Transmission start level (def:AUTO) ?<br />

PORT 201> Remote unit (def:) ?<br />

PORT 201> Class (def:3) ?<br />

PORT 201> Remote port number (1-65534,def:201) ?<br />

• These are the same parameters as those for a built-in serial port.<br />

Caution: The Dual Serial interface card for the SDM-9360, SDM-9380 and<br />

SDM-9585 does not support Fallback.<br />

7-4 Memotec Inc.