<strong>Legacy</strong> <strong>Data</strong><br />

1.3 Configuring an HDLC Connection<br />

The PORT or SLOT submenu of the SETUP console command includes all parameters<br />

required to configure an HDLC port.<br />

If you are using SNMP, the required configuration variables are grouped under the ifwan<br />

category. For text-based configuration the [ifwan#] heading is used, where # represents<br />

the number of the port or channel.<br />

An HDLC port can be configured on a serial port (including ports built into the base unit<br />

and ports on the Dual Serial Port interface card) or a channel on a digital interface card.<br />

• To configure a built-in serial port on the base unit as an HDLC port:<br />

- Enter the menu sequence: SE � PORT.<br />

- Select the Port number.<br />

- Set the Protocol to HDLC.<br />

- Change the other port parameters from their default values, if desired.<br />

• To configure a digital channel or a serial port on the Dual Serial interface card as<br />

an HDLC port:<br />

- Enter the menu sequence: SE � SLOT.<br />

- Select the Slot number.<br />

- On a digital interface card only: enter CHANNEL at the Item prompt.<br />

- Select the Channel number, e.g. 102, where the first digit indicates the slot<br />

and the last two digits indicate the channel.<br />

- Set the Protocol to HDLC.<br />

- Change the other channel parameters from their default values, if desired.<br />

1.3.1 HDLC Port Configuration<br />

Console SNMP Text-based Config<br />

SE/PORT (serial port)<br />

SE/SLOT (digital channel<br />

or dual serial port)<br />

ifwan (category) [ifwan#] (heading)<br />

When you define a serial port as HDLC, the following port parameters are listed on the<br />

console:<br />

SE/PORT/#/<br />

HDLC example SDM-9230>SE<br />

SETUP<br />

Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />

PHONE/<br />

PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />

def:BRIDGE) ? PORT<br />

Port number (ETH1/ETH2/CSL/1,def:1) ?<br />

1-4 Memotec Inc.