8.2 Configuring a COP Connection<br />
COP Protocol<br />
The PORT or SLOT submenu of the SETUP console command includes all parameters<br />
required to configure a COP port.<br />
If you are using SNMP, the required configuration variables are grouped under the ifwan<br />
category. For text-based configuration the [ifwan#] heading is used, where # represents<br />
the number of the port or channel.<br />
A COP port can be configured on a built-in serial port or a serial port on a Dual Serial Port<br />
interface card.<br />
• To configure a built-in serial port on the base unit as a COP port:<br />
- Enter the menu sequence: SE � PORT.<br />
- Select the Port number.<br />
- Set the Protocol to COP.<br />
- Change the other port parameters from their default values, if desired.<br />
• To configure a serial port on the Dual Serial interface card as a COP port:<br />
- Enter the menu sequence: SE � SLOT.<br />
- Select the Slot number.<br />
- Select the Channel number, e.g. 102, where the first digit indicates the slot<br />
and the last two digits indicate the channel.<br />
- Set the Protocol to COP.<br />
- Change the other parameters from their default values, if desired.<br />
8.2.1 COP on a Built-in Serial Port<br />
SE/PORT/#/<br />
COP example<br />
Console SNMP Text-based Config<br />
SE/PORT (serial port)<br />
SE/SLOT (digital channel<br />
or dual serial port)<br />
ifwan (category) [ifwan#] (heading)<br />
When you define a serial port with the COP protocol, the following port parameters are<br />
listed on the console:<br />
SDM-9230>SE<br />
SETUP<br />
Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />
PHONE/<br />
PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />
def:BRIDGE) ? PORT<br />
Port number (ETH1/ETH2/CSL/1,def:1) ?<br />
PORT 1> Protocol (def:BSC) ? COP<br />
PORT 1> Interface...............................DCE-V35<br />
PORT 1> Clocking mode (def:INTERNAL) ?<br />
Memotec Inc. 8-3