13.4.6 BAN/BNN transmission window size<br />
SE/PU Configuration Parameters<br />
For all PU modes with a BAN or BNN connection.<br />
Maximum transmission window size on the BAN or BNN connection. The dynamic<br />
window algorithm increases the window size by one each time the number of frames<br />
defined by the BAN/BNN Dynamic Window parameter (see below) has been<br />
acknowledged without a retransmission, until the maximum value defined by the BAN/<br />
BNN Window parameter has been reached. The window size is reset to 1 when a<br />
retransmission occurs.<br />
13.4.7 BAN/BNN dynamic window<br />
Console SNMP Text-based Config<br />
BAN/BNN transmission<br />
window size<br />
Values: 1 - 31<br />
Default: 7<br />
puBanBnnWindow [pu#] BanBnnWindow<br />
Console SNMP Text-based Config<br />
BAN/BNN dynamic window<br />
puBanBnnNw [pu#] BanBnnNw<br />
For all PU modes with a BAN or BNN connection.<br />
Number of information frames that are consecutively acknowledged without a<br />
retransmission before the window size will be incremented by one. This parameter is used<br />
for the dynamic window algorithm, in conjunction with the BAN/BNN Window<br />
parameter (explained above).<br />
Values: 1 - 1000<br />
Default: 10<br />