13.4.6 BAN/BNN transmission window size<br />

SE/PU Configuration Parameters<br />

For all PU modes with a BAN or BNN connection.<br />

Maximum transmission window size on the BAN or BNN connection. The dynamic<br />

window algorithm increases the window size by one each time the number of frames<br />

defined by the BAN/BNN Dynamic Window parameter (see below) has been<br />

acknowledged without a retransmission, until the maximum value defined by the BAN/<br />

BNN Window parameter has been reached. The window size is reset to 1 when a<br />

retransmission occurs.<br />

13.4.7 BAN/BNN dynamic window<br />

Console SNMP Text-based Config<br />

BAN/BNN transmission<br />

window size<br />

Values: 1 - 31<br />

Default: 7<br />

puBanBnnWindow [pu#] BanBnnWindow<br />

Console SNMP Text-based Config<br />

BAN/BNN dynamic window<br />

puBanBnnNw [pu#] BanBnnNw<br />

For all PU modes with a BAN or BNN connection.<br />

Number of information frames that are consecutively acknowledged without a<br />

retransmission before the window size will be incremented by one. This parameter is used<br />

for the dynamic window algorithm, in conjunction with the BAN/BNN Window<br />

parameter (explained above).<br />

Values: 1 - 1000<br />

Default: 10<br />

Memotec Inc. 13-17