Legacy Data System Reference - Comtech EF Data
Legacy Data System Reference - Comtech EF Data
Legacy Data System Reference - Comtech EF Data
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
BSC Protocol<br />
At the remote end, the composite link information is decompressed and passed to the<br />
transmitter which then transmits the data. The transmitter can be started on the first cell if<br />
fallback is enabled, or on the complete frame if fallback is disabled.<br />
7.3 Configuring a BSC Connection<br />
The PORT or SLOT submenu of the SETUP console command includes all parameters<br />
required to configure a BSC port.<br />
If you are using SNMP, the required configuration variables are grouped under the ifwan<br />
category. For text-based configuration the [ifwan#] heading is used, where # represents<br />
the number of the port or channel.<br />
A BSC port can be configured on a built-in serial port or a serial port on a Dual Serial Port<br />
interface card.<br />
• To configure a built-in serial port on the base unit as a BSC port:<br />
- Enter the menu sequence: SE � PORT.<br />
- Select the Port number.<br />
- Set the Protocol to BSC.<br />
- Change the other port parameters from their default values, if desired.<br />
• To configure a serial port on the Dual Serial interface card as a BSC port:<br />
- Enter the menu sequence: SE � SLOT.<br />
- Select the Slot number.<br />
- Select the Channel number, e.g. 102, where the first digit indicates the slot<br />
and the last two digits indicate the channel.<br />
- Set the Protocol to BSC.<br />
- Change the other parameters from their default values, if desired.<br />
7.3.1 BSC on a Built-in Serial Port<br />
SE/PORT/#/<br />
BSC example<br />
Console SNMP Text-based Config<br />
SE/PORT (serial port)<br />
SE/SLOT (dual serial port)<br />
ifwan (category) [ifwan#] (heading)<br />
When you define a serial port with the BSC protocol, the following port parameters are<br />
listed on the console:<br />
SDM-9230>SE<br />
SETUP<br />
Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />
PHONE/<br />
Memotec Inc. 7-3