02.02.2013 Views

Legacy Data System Reference - Comtech EF Data

Legacy Data System Reference - Comtech EF Data

Legacy Data System Reference - Comtech EF Data

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Legacy</strong> <strong>Data</strong><br />

• IPL: This value is available only for WAN/user ports configured with a DCE<br />

interface and an SDLC or HDLC protocol. The unit provides two clock signals<br />

exactly in phase: one on RS-232 pin 15 (V.35 pins V-X) to clock the transmitted<br />

data, and one on RS-232 pin 17 (V.35 pins Y-AA) to clock the received data. This<br />

clock mode may be required on an IBM 3174 controller when fallback is used.<br />

NOTE: The Dual Serial interface card for the SDM-9360, SDM-9380 and SDM-9585<br />

does not support IPL clocking mode.<br />

Values: (Non-asynchronous ports): INTERNAL, EXTERNAL, IPL<br />

Default: For DCE interface: INTERNAL<br />

for DTE interface: EXTERNAL<br />

Here are the possible settings of the Clocking Mode parameter for asynchronous ports<br />

(T-ASYNC, R-ASYNC and asynchronous PPP):<br />

• ASYNC: No physical clocking is used. This value permits sampling using the<br />

internal clock on the NetPerformer processor.<br />

• ISO-INT: Configures the asynchronous port with an internal isochronous clock<br />

source. Here the clock is external to the data, but is generated by the NetPerformer.<br />

• ISO-EXT: Configures the port with an external isochronous clock source. This<br />

clock is external to the data, and is received by the NetPerformer from an external<br />

source.<br />

Values: (Asynchronous ports only): ASYNC, ISO-INT, ISO-EXT<br />

Default: ASYNC<br />

12-4 Memotec Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!