<strong>Legacy</strong> <strong>Data</strong><br />
13.3.9 LLC frame size<br />
13.3.10 XID support<br />
Console SNMP Text-based Config<br />
LLC frame size puLlcMaxFrame [pu#] LlcMaxFrame<br />
For all PU modes with an LLC connection.<br />
Maximum frame size on the LLC side of the connection, excluding LLC and SNA<br />
headers.<br />
For an SDLC-LLC connection, if the value of this parameter is equal to that of the SDLC<br />
Frame Size parameter (listed earlier), then no frame splitting will occur. On the other<br />
hand, if the value of this parameter is different from that of the SDLC Frame Size<br />
parameter, the NetPerformer will split the frames according to the smaller Frame Size<br />
value.<br />
Values: 128, 256, 512, 1024<br />
Default: 512<br />
Console SNMP Text-based Config<br />
XID support puXid [pu#] Xid<br />
For all PU modes with an LLC, BAN or BNN connection.<br />
PU exchanges identification. This parameter determines whether the PU expects to<br />
exchange PU identification with the device it is connected to, and ensures the identity of<br />
the remote PU in SNA applications. When set to AUTO, the NetPerformer can get the PU<br />
ID automatically via the XID request, and pass it to the host side before completing the<br />
connection.<br />
If the PU does not support the XID request, you must set this parameter to MANUAL. In<br />
this case, you will have to set the XID manually by completing the XID fields if the host<br />
requests this information.<br />
NOTE: This parameter is slightly different from the XID Support parameter mentioned<br />
earlier (for configuration of an SDLC connection), where the manual<br />
setting is not available.<br />
Values: AUTO, MANUAL<br />
Default: AUTO<br />
13-12 Memotec Inc.