02.02.2013 Views

Legacy Data System Reference - Comtech EF Data

Legacy Data System Reference - Comtech EF Data

Legacy Data System Reference - Comtech EF Data

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Legacy</strong> <strong>Data</strong><br />

PORT 1> Port speed (bps) (1200-64000,def:56000) ?<br />

PORT 1> Fallback speed (def:ENABLE) ?<br />

PORT 1> Modem control signal (def:STATIC) ?<br />

PORT 1> Transmission start level (def:AUTO) ?<br />

PORT 1> Idle (def:MARK) ?<br />

PORT 1> Synchronization character (def:1616) ?<br />

PORT 1> Number of desynch. characters (1-100,def:3) ?<br />

PORT 1> Desynchronization character (def:FF) ?<br />

PORT 1> Remote unit (def:) ? CHICAGO-9230<br />

PORT 1> Class (def:3) ?<br />

PORT 1> Remote port number (1-65534,def:1) ?<br />

• Protocol, Interface, Clocking mode, Port speed (bps), Fallback speed, Modem<br />

control signal, Transmission start level, Idle, Remote unit, Class and Remote port<br />

number are common to other legacy data protocols, and are detailed in SE/PORT<br />

Configuration Parameters on page 1.<br />

• Synchronization character, Number of desynch. characters and Desynchronization<br />

character are unique to the COP protocol. Refer to COP Port on page 19 for<br />

details.<br />

8.2.2 COP on the Dual Serial Interface Card<br />

SE/SLOT/<br />

Channel/COP<br />

example<br />

When you define a serial port on the Dual Serial interface card with the COP protocol, the<br />

following parameters are listed on the console:<br />

SDM-9230>SE<br />

SETUP<br />

Item (BRIDGE/CALLER ID/CLASS/CUSTOM/FILTER/GLOBAL/HUNT/IP/IPX/MAP/<br />

PHONE/<br />

PORT/PU/PPPOE/PPPUSER/PVC/REDUNDANCY/SCHEDULE/SLOT/USER/VLAN,<br />

def:BRIDGE) ? SLOT<br />

SLOT> Slot number (1/2/3,def:2) ?<br />

SLOT> Channel Number (201-202/ALL,def:201) ? 202<br />

PORT 202> Protocol (def:OFF) ? COP<br />

PORT 202> Interface.............................DTE-V35<br />

PORT 202> Clocking mode (def:EXTERNAL) ?<br />

PORT 202> Modem control signal (def:STATIC) ?<br />

PORT 202> Transmission start level (def:AUTO) ?<br />

PORT 202> Idle (def:MARK) ?<br />

PORT 202> Synchronization character (def:1616) ?<br />

PORT 202> Number of desynch. characters (1-100,def:3) ?<br />

PORT 202> Desynchronization character (def:FF) ?<br />

PORT 202> Remote unit (def:) ?<br />

PORT 202> Class (def:3) ?<br />

PORT 202> Remote port number (1-65534,def:202) ?<br />

• These are the same parameters as those for a built-in serial port.<br />

Caution: The Dual Serial interface card for the SDM-9360, SDM-9380 and<br />

SDM-9585 does not support Fallback.<br />

8-4 Memotec Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!