40-5124-24C IFU, ProPort.indd - Smiths Medical
40-5124-24C IFU, ProPort.indd - Smiths Medical
40-5124-24C IFU, ProPort.indd - Smiths Medical
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
E. Références bibliographiques<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9.<br />
10.<br />
Klotz HP, Schopke W, Kohler A, Pestalozzi B, Largiader F. Catheter Fracture: A Rare<br />
Complication of Totally Implantable Subclavian Venous Access Devices. J Surgical<br />
Oncol 1996; 62:222.<br />
Vadlamani P, Dawn B, Perry MC. Catheter Fracture and Embolization from Totally<br />
Implanted Venous Access Ports. J Vascular Dis 1998; 12:1013.<br />
Monsuez JJ, Douard MC, Martin-Bouyer Y. Catheter Fragments Embolization. J<br />
Vascular Dis 1997; 2:117.<br />
Ramsden WH, Cohen AT, Blanshard KS. Case Report: Central Venous Catheter Fracture<br />
Due to Compression Between the Clavicle and First Rib. Clinical Radiology 1995; 50:59.<br />
Coles CE, Whitear WP, Le Vay JH. Spontaneous Fracture and Embolization of a Central<br />
Venous Catheter: Prevention and Early Detection. Clinical Oncology 1998; 10:412.<br />
Kossoff EH, Poirier MP. Peripherally inserted central venous catheter fracture and<br />
embolization to the lung. Pediatric Emer Care 1998; 6:<strong>40</strong>3.<br />
Lafreniere R. Indwelling Subclavian Catheters and a Visit With the “Pinched-Off Sign”.<br />
J Surgical Oncol 1991; 47:261.<br />
Hinke DH, Zandt-Stastny DA, Goodman LR, Quebbeman EJ, Krzywda EA, Andris<br />
DA. Pinch-off Syndrome: A Complication of Implantable Subclavian Venous Access<br />
Devices. Radiology 1990; 177:353<br />
Franey T, Demarco LC, Geiss AC, Ward RJ. Catheter fracture and embolization in a<br />
totally implanted venous access catheter. J Parent Ent Nutr 1988; 12:528<br />
Moureau NL, McKinnon BT, Douglas CM. Multidisciplinary management of thrombotic<br />
catheter occlusions. J Vasc Acces Dev 1999; summer:22<br />
REMARQUE : Le médecin est informé de la date de publication de ce Mode<br />
d’emploi. Si le produit est utilisé plus d’une année après cette date, le médecin<br />
est prié de contacter Deltec Inc., pour vérifier si une édition plus récente de ce<br />
Mode d’emploi est disponible.<br />
Date de publication : 2005-06<br />
Les produits décrits ci-dessous font l’objet d’un/des brevet(s) US suivants : 4,723,948,<br />
4,743,231, 4,880,414, 4,963,133, 5,387,192, 5,558,641 et 5,613,945 ; autre(s) brevet(s) en<br />
instance ; brevet(s) étranger(s) en instance.<br />
<strong>ProPort</strong>, SlideLock, CATH-SHIELD, PORT-A-CATH et Low Profile sont des marques commerciales<br />
de la <strong>Smiths</strong> <strong>Medical</strong> famille d’entreprises. Le symbole indique que la marque<br />
a été enregistrée auprès du Registre des brevets et des marques ® commerciales aux États-<br />
Unis et dans certains autres pays.<br />
© 2005 <strong>Smiths</strong> <strong>Medical</strong> famille d’entreprises. Tous droits réservés.<br />
[de]<br />
INHALT SEITE<br />
I. EINFÜHRUNG .......................................................................................... 15<br />
A. Produktbeschreibung ............................................................................................... 16<br />
B. Anwendungsgebiete ................................................................................................. 16<br />
C. Gegenanzeigen .......................................................................................................... 16<br />
D. Mögliche Komplikationen ...................................................................................... 16<br />
II. WARNHINWEISE ...................................................................................... 16<br />
III. HINWEISE ZUR VORBEREITUNG DER IMPLANTATION .......................... 17<br />
A. Vorbereitung des Systems ....................................................................................... 17<br />
A.1 Nicht fertig montierte Systeme ..................................................................... 17<br />
A.2 Fertig montierte Systeme ............................................................................... 17<br />
IV. VERFAHREN FÜR DIE KATHETERPLAZIERUNG ...................................... 17<br />
A. Perkutane Punktion – Methode A (Chirurgie-Radiologen) ............................ 17<br />
B. Perkutane Punktion – Methode B (Chirurgen) .................................................. 18<br />
C. Chirurgische Inzision .............................................................................................. 18<br />
V. VORBEREITUNG DER PORTSTELLE ........................................................ 18<br />
A. Vorbereitung der subkutanen Tasche ................................................................... 18<br />
B. Montage des Katheters am Port ............................................................................. 19<br />
B.1 SlideLock Sicherungsring ............................................................................ 19<br />
B.2 CATH-SHIELD® Sicherungsring ................................................................. 19<br />
C. Überprüfen des Durchflusses ................................................................................. 19<br />
D. Schließen der Inzision ............................................................................................. 19<br />
E. Postoperative Pflege ................................................................................................. 19<br />
VI. HINWEISE ZUR ANWENDUNG ................................................................ 20<br />
A. Bestimmung der Systemintegrität ......................................................................... 20<br />
A.1 Systemintegrität ist bestätigt – Port wird nicht sofort verwendet ......... 20<br />
A.2 Systemintegrität bestätigt – Injektion oder Infusion wird sofort<br />
eingeleitet .......................................................................................................... 20<br />
B. Regelmäßige Spülung ............................................................................................... 21<br />
C. Blutabnahme .............................................................................................................. 21<br />
D. Beendigung des Systemeinsatzes ........................................................................... 21<br />
E. Literaturhinweise ...................................................................................................... 21<br />
ABBILDUNGEN ................................................................................................ 77<br />
I. EINFÜHRUNG<br />
<strong>ProPort</strong> implantierbare venöse Systeme können im Arm bzw. in der Brust implantiert<br />
werden und ermöglichen den wiederholten Zugang zum venösen System<br />
zur parenteralen Zufuhr von Medikamenten, Flüssigkeiten und Nährlösungen<br />
sowie zur Abnahme von venösem Blut. Diese Produkte dürfen ausschließlich von<br />
Ärzten implantiert werden, die über ausreichende Erfahrung und Ausbildung in<br />
der Implantation und Wartung von venösen Kathetern verfügen und Kenntnis<br />
über die damit verbundenen Risiken haben.<br />
WARNHINWEISE: Patienten, die Berufe oder Aktivitäten ausüben, welche übermäßige<br />
bzw. wiederholte Bewegungsbeanspruchung der oberen Extremitäten,<br />
der Schulter oder des Brustkorbes erfordern, wie z.B. Golfspielen, Schwimmen<br />
oder Gewichtheben, sind darauf aufmerksam zu machen, daß derartige<br />
Aktivitäten das Risiko einer Katheterfragmentierung durch eine Einklemmung<br />
des Katheters zwischen der Klavikula und der ersten Rippe erhöhen (catheter<br />
pinch-off syndrome). 1,2,3,4,5,7,8,9<br />
Informationsblätter für Patienten und Ärzte können bei <strong>Smiths</strong> <strong>Medical</strong> MD, Inc.<br />
in den USA unter der Tel.-Nr. 1 800.426.2448 oder beim europäischen Vertragshändler<br />
<strong>Smiths</strong> <strong>Medical</strong> International Ltd., unter der Tel.-Nr. +44 (0)1923 246434<br />
bezogen werden.<br />
15