5.4 “AW” PANEL<br />

Page 7.1-46<br />

Revision: 2<br />

August 2011<br />

<strong>ERECTION</strong> <strong>AND</strong> <strong>SAFETY</strong> <strong>MANUAL</strong><br />

The “AW” panels are designed for wall applications only. The inverted ribs incorporated into its design produce<br />

smooth shadow lines and semi-concealed fasteners. Sheeting can begin from either end of the building, and<br />

application of the architectural panel is not directional. Properly installed, the lap edges of the “AW” panel will<br />

have minimum visibility.<br />

NOTE:<br />

The “AW” adversely affected by an uneven girt line, and I or insulation that causes an uneven girt line. Either<br />

situation could cause oil canning in the panels.<br />

The design of the panel lap allows for the panel edge to be visible when installed. Equipment limitations and<br />

manufacturing tolerances, as well as other factors can contribute to waviness at the visible edge.<br />

12"<br />

6" 6"<br />

NOTE:<br />

Do not apply pressure to the pan of the panels during installation, when the pressure is released,<br />

“oil canning” will occur. <strong>SAFETY</strong> FIRST!<br />

36"<br />

PANEL LAP<br />

1 1 4"<br />

Technical information contained herein is subject to change without notice.