<strong>ERECTION</strong> <strong>AND</strong> <strong>SAFETY</strong> <strong>MANUAL</strong><br />
5.20 PEAK PANEL INSTALLATIONS<br />
Die formed ridge panels are to be installed as each side of the roof is sheeted. This will aid in keeping both<br />
sides of the roof aligned. After having installed a run of panels on each side of the roof, apply sealant to the<br />
panels as shown. Set die formed ridge panel in place and install lap and purlin fasteners. Apply tape sealant<br />
along the top of the leading rib to prepare for the next sidelap.<br />
ROOF FASTENER<br />
TAPE SEALANT<br />
NOTE:<br />
Do not walk on unsecured ends of panels.Safety fi rst!<br />
PEAK PANEL<br />
PEAK PURLINS<br />
TAPE SEALANT<br />
SEE BUILDING <strong>ERECTION</strong> DRAW-<br />
INGS FOR DIMENSION<br />
Technical information contained herein is subject to change without notice. Page 7.1-71<br />
Revision: 2<br />
April 2011