5.19 INSTALLATION OF ROOF PANELS<br />
Page 7.1-70<br />
Revision: 2<br />
August 2011<br />
<strong>ERECTION</strong> <strong>AND</strong> <strong>SAFETY</strong> <strong>MANUAL</strong><br />
With the fi rst panel run installed and secured, and sidelap sealant applied, the second panel run may be<br />
started. Prepare the eave with an inside closure and tape sealant as shown previously. Position the panel<br />
so that the overlapping ribs will nest properly. Be sure to check for proper overhang and panel coverage.<br />
Stitch the major ribs of the two panels together, and fasten panel to the purlins.<br />
BLANKET<br />
INSULATION<br />
EAVE<br />
STRUT<br />
DOUBLE<br />
SIDED TAPE<br />
EAVE FLASHING<br />
TAPE SEALANT<br />
WALL PANEL<br />
NOTE:<br />
Sweep up all drill shavings from panels at end of each work period<br />
to avoid surface rust and damage to panel fi nish.<br />
Technical information contained herein is subject to change without notice.