<strong>ERECTION</strong> <strong>AND</strong> <strong>SAFETY</strong> <strong>MANUAL</strong><br />
5.14 SEALING THE SIDELAP<br />
Apply the sidelap tape sealant to the weather side edge of the lower panel’s major rib as shown. The tape<br />
sealant should only be applied to clean, dry surfaces. With the release paper in place, press fi rmly along<br />
the length of the sealant to insure proper adhesion. In removing the protective paper from the tape sealant,<br />
care should be taken not to pull the tape sealant away from the panel. Install the adjoining panel positioning<br />
the overlapping rib with care. Drill, at the center of the clearance holes in the overlapping panel, 1/8“<br />
pilot holes for the lap fasteners. Stitch the lap with the No. 14 self-tapping fasteners supplied with the job.<br />
Never allow the sealant to be placed in other locations.<br />
PREVAILING WIND DIRECTION<br />
PANEL RIB<br />
1/4” CLEARANCE HOLE<br />
ROOF PANEL<br />
1/8” PILOT HOLE<br />
ROOF FASTENER<br />
TAPE SEALANT<br />
ROOF PANEL<br />
NOTE:<br />
Use OSHA approved eye protection when operating a drill. Sweep up all<br />
drill shavings from panels at end of each work period to minimize surface<br />
rust and damage to panel fi nish Safety fi rst!.<br />
Technical information contained herein is subject to change without notice. Page 7.1-65<br />
Revision: 2<br />
April 2011