<strong>Oak</strong> <strong>Ridge</strong> <strong>Reservation</strong><br />

Fig. 3.24. Demolition debris generated from K-1035 building<br />

being sent to EMWMF.<br />

Park Storm Water Pollution Prevention Program Sampling and Analysis Plan (BJC/OR-758/R8). All<br />

guidelines stated in the ETTP SWPP Program Sampling and Analysis Plan concerning sample<br />

documentation, analytical procedures, Quality Assurance / Quality Control, etc. were followed as part of<br />

this sampling effort.<br />

The metals results from the sampling performed in conjunction with the Building K-1035 D&D are<br />

presented in Figs. 3.25, 3.26, and 3.27. The figures indicate that:<br />

• With the exception of arsenic, all metals were present at higher concentrations in the “during<br />

demolition” samples collected in summer 2009 compared to the “before demolition samples”<br />

collected in November 2008;<br />

• With the exception of arsenic, all metals were present at concentrations at or near the Water Quality<br />

Criteria for the given metal;<br />

• Metal results were fairly consistent between the three manholes; and,<br />

• Improvements in the sediment controls in the Building K-1035 demolition area may have been<br />

needed to provide more effective removal of contaminants from the storm water runoff from the area.<br />

The VOC results from the sampling performed in conjunction with the Building K-1035 D&D are<br />

presented in Figs. 3.28, 3.29, and 3.30. The figures indicate that:<br />

• No clear conclusions can be drawn from the VOC results from samples collected as part of the<br />

Building K-1035 sampling effort;<br />

• Many of the results showed VOCs at non-detectable levels; and,<br />

• The concentration of VOCs in the three manholes sampled does not appear to have been affected by<br />

the demolition of Building K-1035.<br />