Installation and<br />

Travel Sensor Alignment<br />

Travel Sensor Alignment<br />

Table 2 shows the general guidelines for travel sensor alignment. Review the<br />

table prior to installing the <strong>SVI</strong> <strong>II</strong> <strong>ESD</strong> on a rotary valve actuator for proper<br />

alignment of the magnet.<br />

Table 2 Travel Sensor Alignment<br />

Rotary<br />

Mounting<br />

System<br />

Stroke Direction<br />

Magnet<br />

Orientation<br />

Valve<br />

Position<br />

Sensor<br />

Counts<br />

Rotary<br />

60° Rotation<br />

Clockwise with<br />

increasing setpoint<br />

Full Open<br />

or<br />

Full Closed<br />

-8000 +/- 1500<br />

or<br />

+8000 +/- 1500<br />

(-45°)<br />

>60° Rotation<br />

Counter Clockwise<br />

rotation with increasing<br />

setpoint<br />

Full Open<br />

or<br />

Full Closed<br />

-8000 +/- 1500<br />

or<br />

+8000 +/- 1500<br />

(+45°)<br />

General Rule for<br />

other<br />

configurations<br />

Any amount of rotation<br />

Clockwise or<br />

counterclockwise<br />

50% Travel<br />

(Mid-Stroke)<br />

0 +/- 1000<br />

(0°)<br />