Installation and<br />
Travel Sensor Alignment<br />
Travel Sensor Alignment<br />
Table 2 shows the general guidelines for travel sensor alignment. Review the<br />
table prior to installing the <strong>SVI</strong> <strong>II</strong> <strong>ESD</strong> on a rotary valve actuator for proper<br />
alignment of the magnet.<br />
Table 2 Travel Sensor Alignment<br />
Rotary<br />
Mounting<br />
System<br />
Stroke Direction<br />
Magnet<br />
Orientation<br />
Valve<br />
Position<br />
Sensor<br />
Counts<br />
Rotary<br />
60° Rotation<br />
Clockwise with<br />
increasing setpoint<br />
Full Open<br />
or<br />
Full Closed<br />
-8000 +/- 1500<br />
or<br />
+8000 +/- 1500<br />
(-45°)<br />
>60° Rotation<br />
Counter Clockwise<br />
rotation with increasing<br />
setpoint<br />
Full Open<br />
or<br />
Full Closed<br />
-8000 +/- 1500<br />
or<br />
+8000 +/- 1500<br />
(+45°)<br />