<strong>GE</strong> <strong>Energy</strong><br />

<strong>SVI</strong> <strong>II</strong> <strong>ESD</strong> Quick Start<br />

Table 16 Pneumatics Single Acting Standard Flow (Continued)<br />

Air Supply<br />

Air Consumption<br />

Dry, oil-free, 5 micron filtered air (See ISA S7.3)<br />

0.212 scfm (6 slm) at 30 psi (2.1 bar, 207 kPa)<br />

supply<br />

0.282 scfm (8 slm) at 60 psi (4.14 bar, 414 kPa)<br />

supply<br />

0.424 scfm (12 slm) at 90 psi (6.21 bar, 621 kPa)<br />

supply<br />

0.529 scfm (15 slm) at 120 psi (8.28 bar, 828 kPa)<br />

supply<br />

Air Supply Failure On supply failure the actuator output P1 falls to 0<br />

psi.<br />

Loss of Input Signal<br />

Output Pressure<br />

Output drops to low pressure.<br />

120 psi (8.28 bar, 828 kPa) max<br />

Table 17 Pneumatics Double Acting Standard Flow<br />

Air Supply Dry, oil-free, 5 micron filtered air see ISA S7.3<br />

Action<br />

Supply Pressure<br />

for Double Acting<br />

Air Delivery for <br />

Double Acting<br />

Air Capacity<br />

(flow coefficient)<br />

Output 1 increases with increasing signal<br />

Output 2 decreases with increasing signal<br />

30 - 120 psi max. (2.07 - 8.27 bar, 207 - 827 kPa)<br />

Do not exceed actuator rating.<br />

7.77 scfm (220 slm) filling and venting at 30 psi (2.1 bar, 207 kPa)<br />

supply<br />

13.06 scfm (370 slm) filling and venting at 60 psi (4.14 bar, 414<br />

kPa) supply<br />

18.36 scfm (520 slm) filling and venting at 90 psi (6.21 bar, 621<br />

kPa) supply<br />

23.48 scfm (665 slm) filling and venting at 120 psi (8.28 bar, 828<br />

kPa) supply<br />

Loading CV = 0.39<br />

Venting CV = 0.33<br />