Material<br />

TECAPEEK<br />

CF30 MT<br />

TECAPEEK<br />

CLASSIX<br />

white<br />

TECAPEEK<br />

TS<br />

TECAPEEK<br />

CMF<br />

TECAPEEK<br />

CMF<br />

grey<br />

TECAPEEK<br />

HT<br />

black<br />

TECAPEEK<br />

ST<br />

black<br />

TECATEC<br />

PEEK CW50<br />

TECATEC TECATOR<br />

PEKK CW60 5013<br />

Chemical Designation<br />

PEEK PEEK PEEK PEEK PEEK PEK PEKEKK PEEK PEKK PAI<br />

Fillers<br />

carbon<br />

fibres<br />

mineral<br />

filler<br />

ceramic<br />

ceramic<br />

Density<br />

(DIN EN ISO 1183)<br />

Mechanical properties<br />

Modulus of elasticity (tensile test)<br />

(DIN EN ISO 527-2)<br />

Tensile strength<br />

(DIN EN ISO 527-2)<br />

Tensile strength at yield<br />

(DIN EN ISO 527-2)<br />

Elongation at yield<br />

(DIN EN ISO 527-2)<br />

Elongation at break<br />

(DIN EN ISO 527-2)<br />

Modulus of elasticity (flexural test)<br />

(DIN EN ISO 178)<br />

Flexural strength<br />

(DIN EN ISO 178)<br />

Compression modulus<br />

(EN ISO 604)<br />

Compressive strength (1% / 2%)<br />

(EN ISO 604)<br />

Impact strength (Charpy)<br />

(DIN EN ISO 179-1eU)<br />

Notched impact strength (Charpy)<br />

(DIN EN ISO 179-1eA)<br />

Ball intendation hardness<br />

(ISO 2039-1)<br />

<strong>The</strong>rmal properties<br />

Glass transition temperature<br />

(DIN 53765)<br />

Melting temperature<br />

(DIN 53765)<br />

Service temperature,<br />

short term<br />

Service temperature,<br />

long term<br />

<strong>The</strong>rmal expansion (CLTE),<br />

23 – 60 °C (DIN EN ISO 11359-1;2)<br />

<strong>The</strong>rmal expansion (CLTE),<br />

23 – 100 °C (DIN EN ISO 11359-1;2)<br />

Specific heat<br />

(ISO 22007-4:2008)<br />

<strong>The</strong>rmal conductivity<br />

(ISO 22007-4:2008)<br />

Electrical properties<br />

Surface resistance<br />

(DIN IEC 60093)<br />

Miscellaneous data<br />

Water absorption 24h / 96h (23 °C)<br />

(DIN EN ISO 62)<br />

Resistance<br />

to hot water / bases<br />

Resistance to weathering<br />

Flammability (UL94)<br />

(DIN IEC 60695-11-10;)<br />

[g / cm³]<br />

[MPa]<br />

[MPa]<br />

[MPa]<br />

[%]<br />

[%]<br />

[MPa]<br />

[MPa]<br />

[MPa]<br />

[MPa]<br />

[kJ / m²]<br />

[kJ / m²]<br />

[MPa]<br />

[°C]<br />

[°C]<br />

[°C]<br />

[°C]<br />

[10 -5 K -1 ]<br />

[10 -5 K -1 ]<br />

[J / (g*K)]<br />

[W/(m*K)]<br />

[Ω]<br />

[%]<br />

1.42 1.4 1.49 1.65 1.65 1.31 1.32 1.49 1.61 1.4<br />

6,000 4,700 5,700 5,500 5,500 4,600 4,600 53,200 54,300 3,800<br />

115 117 110 105 105 120 134 491 585 151<br />

115 117 110 102 102 120 134 151<br />

5 5 4 3 4 4 5<br />

5 11 4 4 5 5 13 21<br />

6,000 4,400 5,900 5,500 5,500 4,600 4,600 48,900 50,900 3,900<br />

188 177 175 170 170 192 193 813 960<br />

4,500 3,500 4,300 4,300 4,300 3,500 3,500 4,050 5,100<br />

23 / 44 25 / 45 17 / 34 25 / 46 25 / 46 25 / 45 24 / 42 51 / 509<br />

58 n.b. n.b. 65 35 n.b. n.b.<br />

5 7 4 4 13.2<br />

318 263 290 286 286 282 275 240<br />

146 150 151 151 151 160 165 143 165 280<br />

341 341 339 339 339 375 384 343 380 n.a.<br />

300 300 300 300 300 300 300 270<br />

260 260 260 260 260 260 260 260 260 250<br />

5 5 4 5 5 5 5<br />

5 5 4 5 5 5 5<br />

1.7 1.0 1.0 1.0<br />

0.59 0.30 0.38 0.38 0.29 (c)<br />

10 8 10 14 10 13 10 14 10 13 10 9 10 9 10 18 (d)<br />

0.02 / 0.03 0.02 / 0.03 0.02 / 0.03 0.02 / 0.03 0.02 / 0.03 0.02 / 0.04 0.02 / 0.03<br />

+ + + + + + + + + –<br />

– – – – – (+) (+) – –<br />

V0 V0 V0 V0 V0 V0 V0 V0 V0 V0<br />

<strong>The</strong> corresponding values and information are no minimum<br />

or maximum values, but guideline values that can be used<br />

primarily for comparison purposes for material selection.<br />

<strong>The</strong>se values are within the normal tolerance range of<br />

product properties and do not represent guaranteed property<br />

values. <strong>The</strong>refore they shall not be used for specification<br />

purposes. Unless otherwise noted, these values were<br />

determined by tests at reference dimensions (typically rods<br />

with diameter 40-60 mm according to DIN EN 15860) on<br />

extruded, cast, compression moulded and machined specimens.<br />

As the properties depend on the dimensions of the<br />

semi-finished products and the orientation in the component<br />

(esp. in reinforced grades), the material may not be used<br />

without separate testing under individual circumstances.<br />

Data sheet values are subject to periodic review, the most<br />

recent update can be found at www.ensinger-online.com<br />

Technical changes reserved.<br />

95