Material<br />
TECASINT<br />
2031<br />
TECASINT<br />
2391<br />
TECASINT<br />
4011<br />
TECASINT<br />
4021<br />
TECASINT<br />
4111<br />
TECASINT<br />
4121<br />
TECASINT<br />
5051<br />
TECASINT<br />
5201 SD<br />
TECASINT<br />
8001<br />
Chemical Designation<br />
PI PI PI PI PI PI PAI PAI PTFE<br />
Fillers<br />
40%<br />
graphite<br />
15% molybdenum<br />
disulfide<br />
15%<br />
graphite<br />
15%<br />
graphite<br />
30%<br />
glass fibres<br />
carbon<br />
fibres,<br />
glass fibres<br />
20%<br />
polyimide<br />
Density<br />
(DIN EN ISO 1183)<br />
Mechanical properties<br />
Modulus of elasticity (tensile test)<br />
(DIN EN ISO 527-2)<br />
Tensile strength<br />
(DIN EN ISO 527-2)<br />
Tensile strength at yield<br />
(DIN EN ISO 527-2)<br />
Elongation at yield<br />
(DIN EN ISO 527-2)<br />
Elongation at break<br />
(DIN EN ISO 527-2)<br />
Modulus of elasticity (flexural test)<br />
(DIN EN ISO 178)<br />
Flexural strength<br />
(DIN EN ISO 178)<br />
Compression modulus<br />
(EN ISO 604)<br />
Compressive strength (1% / 2%)<br />
(EN ISO 604)<br />
Impact strength (Charpy)<br />
(DIN EN ISO 179-1eU)<br />
Notched impact strength (Charpy)<br />
(DIN EN ISO 179-1eA)<br />
Ball intendation hardness<br />
(ISO 2039-1)<br />
<strong>The</strong>rmal properties<br />
Glass transition temperature<br />
(DIN 53765)<br />
Melting temperature<br />
(DIN 53765)<br />
Service temperature,<br />
short term<br />
Service temperature,<br />
long term<br />
<strong>The</strong>rmal expansion (CLTE),<br />
23 – 60 °C (DIN EN ISO 11359-1;2)<br />
<strong>The</strong>rmal expansion (CLTE),<br />
23 – 100 °C (DIN EN ISO 11359-1;2)<br />
Specific heat<br />
(ISO 22007-4:2008)<br />
<strong>The</strong>rmal conductivity<br />
(ISO 22007-4:2008)<br />
Electrical properties<br />
Surface resistance<br />
(DIN IEC 60093)<br />
Miscellaneous data<br />
Water absorption 24h / 96h (23 °C)<br />
(DIN EN ISO 62)<br />
Resistance<br />
to hot water / bases<br />
Resistance to weathering<br />
Flammability (UL94)<br />
(DIN IEC 60695-11-10;)<br />
[g / cm³]<br />
[MPa]<br />
[MPa]<br />
[MPa]<br />
[%]<br />
[%]<br />
[MPa]<br />
[MPa]<br />
[MPa]<br />
[MPa]<br />
[kJ / m²]<br />
[kJ / m²]<br />
[MPa]<br />
[°C]<br />
[°C]<br />
[°C]<br />
[°C]<br />
[10 -5 K -1 ]<br />
[10 -5 K -1 ]<br />
[J / (g*K)]<br />
[W/(m*K)]<br />
[Ω]<br />
[%]<br />
1.59 1.54 1.41 1.49 1.46 1.53 1.57 1.54 1.88<br />
6,300 4,400 4,000 4,943 7,000 6,600 5,800 4,500<br />
65 95 130 93 100 34 94 85 15<br />
2.1 2.9 4.5 3 1.7 0.5 3.4 4.0 200<br />
5,200 4,136 4,300 4,930 6,100 6,100 6,625 4,200<br />
87.5 137 180 131 160 113 163 135<br />
2,027 2,200 2,100 2,067 2,500 2,200 2,590<br />
131 253 40 208 250 200 260 240<br />
14.2 87 24.4 24 11 27.3 17.8<br />
3.3 9.6 4.8 1.1 1.4 5.1 2.8<br />
370 (a) 370 (a) 260 (a) 260 (a) n.a. (a) n.a. (a) 340 (a) 340 (a) 20 (a)<br />
– – 300 300 250<br />
1.04 1<br />
0.4 (b) 0.35 (b) 0.25 (b)<br />
10 16 (d) 10 16 (d) 10 14 10 11<br />
V0 V0 V0 V0 V0 V0 V0 V0 V0<br />
<strong>The</strong> corresponding values and information are no minimum<br />
or maximum values, but guideline values that can be used<br />
primarily for comparison purposes for material selection.<br />
<strong>The</strong>se values are within the normal tolerance range of<br />
product properties and do not represent guaranteed property<br />
values. <strong>The</strong>refore they shall not be used for specification<br />
purposes. Unless otherwise noted, these values were<br />
determined by tests at reference dimensions (typically rods<br />
with diameter 40-60 mm according to DIN EN 15860) on<br />
extruded, cast, compression moulded and machined specimens.<br />
As the properties depend on the dimensions of the<br />
semi-finished products and the orientation in the component<br />
(esp. in reinforced grades), the material may not be used<br />
without separate testing under individual circumstances.<br />
Data sheet values are subject to periodic review, the most<br />
recent update can be found at www.ensinger-online.com<br />
Technical changes reserved.<br />