14. Service menu<br />

4. Use the ▲ or ▼ key to select Overtemp DMD and press ENTER to toggle between [On] and [Off].<br />

On<br />

Off<br />

When temperature is too high, lamp mode is switched from 4 to 2 lamps. The 4 lamps mode can only be restored<br />

after switching first to standby and restarting the projector.<br />

If the temperature exceeds 64 °C, the projector is switched to standby.<br />

for a temperature between 60 and 64 °C the projector continues in normal operation but the warning is set on the<br />

LCD display. Once the temperature is higher then 64 °C, then the projector is switched to standby.<br />

The following text is displayed on the LCD: “DMD temperature to high. Please, check cooling liquid level ! Check<br />

dust filters ! Press any key to confirm.”<br />

Image 14-57<br />

Image 14-56<br />

Image 14-55<br />

R59770057 <strong>CLM</strong> <strong>HD8</strong> 15/03/2010 165