15. Maintenance<br />

WARNING: Switch off the projector and pull out the power cord before starting the check procedure !<br />

How to check<br />

Remove :<br />

- lamp door, see "Removal of the lamp door", page 182.<br />

- front cover, see "Removal of the front cover", page 181.<br />

- back cover, see "Removal of the back cover", page 183.<br />

- top cover, see "Removal of the top cover", page 184.<br />

- side cover, see "Removal of the side cover", page 184.<br />

1. Check the cooling liquid level.<br />

When the white indication line is in the service area, then the reservoir has to be topped-up again. To top-up the reservoir, see<br />

chapter "16. Servicing", "Top-up the reservoir with cooling liquid", page 177.<br />

When the white indication is in the good area, no corrective action should be taken. Close the top cover and fasten both captive<br />

screws.<br />

Image 15-1<br />

Check cooling liquid<br />