E. Troubleshooting<br />
Error<br />
code<br />
Description Error Warning Caused by Action<br />
7908 Fan inlet A low Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
7906 Fan inlet B low Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
7904 Fan lamp 1<br />
back low<br />
7902 Fan lamp 2<br />
back low<br />
7900 Fan lamp 3<br />
back low<br />
7899 Fan lamp 3<br />
back high<br />
7898 Fan lamp 4<br />
back low<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
- Yes<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
7896 Fan prism low Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
7894 Fan color<br />
wheel low<br />
7892 Fan lamp 1<br />
front low<br />
7890 Fan lamp 2<br />
front low<br />
7888 Fan lamp 3<br />
front low<br />
7886 Fan lamp 4<br />
front low<br />
7884 Pump speed<br />
low<br />
7883 Pump speed<br />
high<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Badornowaterflow in the cooling<br />
circuit<br />
If problem persists, call a qualified<br />
service engineer<br />
- Yes Ignore this message<br />
7878 Over temp Yes Yes extreme overheading of DMD or<br />
lamps<br />
If problem persists, call a qualified<br />
service engineer<br />
7877 Under temp DMD too cold Warm up the projector<br />
7876 SMPS input<br />
range<br />
7875 DMD temp<br />
open<br />
7874 DMD temp<br />
short<br />
7873 Ambient temp<br />
open<br />
7872 Ambient temp<br />
short<br />
Supplied voltage is out of range<br />
Check supplied voltage range<br />
Yes Yes Sensor not connected If problem persists, call a qualified<br />
service engineer<br />
Yes Yes short circuit in sensor circuit If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Sensor not connected If problem persists, call a qualified<br />
service engineer<br />
Yes Yes short circuit in sensor circuit If problem persists, call a qualified<br />
service engineer<br />
7871 TEC temp open Yes Yes Sensor not connected If problem persists, call a qualified<br />
service engineer<br />
7870 TEC temp short Yes Yes short circuit in sensor circuit If problem persists, call a qualified<br />
service engineer<br />
7865 Lamp 1 run<br />
time msg<br />
exceeded<br />
7864 Lamp 1 run<br />
time warning<br />
exceeded<br />
7863 Lamp 1 run<br />
time max<br />
exceeded<br />
- Yes Run time of lamp 1 will be exceeded Replace the lamp with a new one.<br />
Call a qualified service engineer<br />
- Yes Run time of lamp 1 is exceeded Replace the lamp with a new one.<br />
Call a qualified service engineer<br />
- Yes The maximum run time for the lamp<br />
is exceeded<br />
Replace the lamp with a new one.<br />
Call a qualified service engineer<br />