5. Connections<br />

max. 3 lamps on<br />

4 lamps on<br />

Light<br />

output %<br />

100<br />

90<br />

70<br />

Image 5-3<br />

110 140 170 264Input<br />

100 voltage V<br />

Power input voltage versus light output (for R90501305)<br />

Input power between 100V and 264V, the maximum light output with 4 lamps can be reached.<br />

Input power between 90V and 99V, 83% of the light output with 4 lamps.<br />

5.2 Input source connections<br />

General<br />

The input and communication unit is equipped with two input slots, which accept any type of input designed for the <strong>CLM</strong> projector.<br />

The modularity of the input modules makes the <strong>CLM</strong> projector very flexible regarding input source connectivity. Note that the slot<br />

numbering is done from top to bottom. So, the uppermost slot is slot number “1”, the second is slot number “2”. All input modules<br />

have two status LED’s. The green LED lights up if the input module is selected as the active input module. The yellow LED lights<br />

up if the input module has detected valid input syncs.<br />

1<br />

2<br />

G<br />

Y<br />

Image 5-4<br />

CAUTION: Always install a cover plate on an unused input slot. This to prevent dust intrusion into the projector.<br />

R59770057 <strong>CLM</strong> <strong>HD8</strong> 15/03/2010 37