E. Troubleshooting<br />
Error<br />
code<br />
Description Error Warning Caused by Action<br />
4198 FPGA PMP init<br />
failed<br />
6099 Board ID<br />
unkown<br />
version<br />
6098 Board ID<br />
invalid string<br />
Yes -<br />
Yes<br />
Yes<br />
7999 DMD temp low Yes Yes Low temperature on DMD turning on the lamp(s) will heat up<br />
the DMD<br />
7998 DMD temp high Yes Yes High temperature on DMD check if air slots are free, clean air<br />
filters.<br />
If problem persists, call a qualified<br />
service engineer.<br />
7997 Ambient temp<br />
low<br />
7996 Ambient temp<br />
high<br />
7995 TEC temp low<br />
7994 TEC temp high Yes Yes<br />
7992 LPS1 temp<br />
high<br />
7990 LPS2 temp<br />
high<br />
7988 LPS3 temp<br />
high<br />
7986 LPS4 temp<br />
high<br />
7978 Lamp4 temp<br />
high<br />
7924 Fan radiator A<br />
low<br />
7922 Fan radiator B<br />
low<br />
7920 Fan outlet A<br />
low<br />
7918 Fan outlet B<br />
low<br />
7916 Fan power<br />
supply A low<br />
7914 Fan power<br />
supply B low<br />
Yes Yes Ambient temperature out of<br />
specifications<br />
Yes Yes Ambient temperature out of<br />
specifications<br />
take measurements to increase the<br />
temperature<br />
check ambient conditions<br />
check if air slots are free, clean air<br />
filter.<br />
Yes Yes High temperature on LPS1 check if air slots are free, clean air<br />
filters.<br />
If problem persists, call a qualified<br />
service engineer.<br />
Yes Yes High temperature on LPS2 check if air slots are free, clean air<br />
filters.<br />
If problem persists, call a qualified<br />
service engineer.<br />
Yes Yes High temperature on LPS3 check if air slots are free, clean air<br />
filters.<br />
If problem persists, call a qualified<br />
service engineer.<br />
Yes Yes High temperature on LPS4 check if air slots are free, clean air<br />
filters.<br />
If problem persists, call a qualified<br />
service engineer.<br />
Yes Yes High temperature on lamp 4 check if air slots are free, clean air<br />
filters.<br />
If problem persists, call a qualified<br />
service engineer.<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
7912 Fan LPS A low Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />
7910 FanLPSBlow Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />
service engineer<br />