E. Troubleshooting<br />

Error<br />

code<br />

Description Error Warning Caused by Action<br />

4198 FPGA PMP init<br />

failed<br />

6099 Board ID<br />

unkown<br />

version<br />

6098 Board ID<br />

invalid string<br />

Yes -<br />

Yes<br />

Yes<br />

7999 DMD temp low Yes Yes Low temperature on DMD turning on the lamp(s) will heat up<br />

the DMD<br />

7998 DMD temp high Yes Yes High temperature on DMD check if air slots are free, clean air<br />

filters.<br />

If problem persists, call a qualified<br />

service engineer.<br />

7997 Ambient temp<br />

low<br />

7996 Ambient temp<br />

high<br />

7995 TEC temp low<br />

7994 TEC temp high Yes Yes<br />

7992 LPS1 temp<br />

high<br />

7990 LPS2 temp<br />

high<br />

7988 LPS3 temp<br />

high<br />

7986 LPS4 temp<br />

high<br />

7978 Lamp4 temp<br />

high<br />

7924 Fan radiator A<br />

low<br />

7922 Fan radiator B<br />

low<br />

7920 Fan outlet A<br />

low<br />

7918 Fan outlet B<br />

low<br />

7916 Fan power<br />

supply A low<br />

7914 Fan power<br />

supply B low<br />

Yes Yes Ambient temperature out of<br />

specifications<br />

Yes Yes Ambient temperature out of<br />

specifications<br />

take measurements to increase the<br />

temperature<br />

check ambient conditions<br />

check if air slots are free, clean air<br />

filter.<br />

Yes Yes High temperature on LPS1 check if air slots are free, clean air<br />

filters.<br />

If problem persists, call a qualified<br />

service engineer.<br />

Yes Yes High temperature on LPS2 check if air slots are free, clean air<br />

filters.<br />

If problem persists, call a qualified<br />

service engineer.<br />

Yes Yes High temperature on LPS3 check if air slots are free, clean air<br />

filters.<br />

If problem persists, call a qualified<br />

service engineer.<br />

Yes Yes High temperature on LPS4 check if air slots are free, clean air<br />

filters.<br />

If problem persists, call a qualified<br />

service engineer.<br />

Yes Yes High temperature on lamp 4 check if air slots are free, clean air<br />

filters.<br />

If problem persists, call a qualified<br />

service engineer.<br />

Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

7912 Fan LPS A low Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />

7910 FanLPSBlow Yes Yes Fan is running too slow or not at all If problem persists, call a qualified<br />

service engineer<br />