11.2.4 SINUSOIDAL POST PROCESSING TOOLS<br />

The POST PROCESSING Dialog gives access to very powerful tools that, once defined,<br />

can be saved, reloaded and automatically be applied to every executed measurement.<br />

Loads a Sinusoidal process.<br />

Saves a Sinusoidal process.<br />

Adds a data value or compatible file to the current measurement.<br />

Subtracts a data value or compatible file to the current measurement.<br />

Multiplies the current measurement by a data value or compatible file.<br />

Divides the current measurement by a data value or compatible file.<br />

Shifts the current measurement by a dB value.<br />

Multiplies the current measurement by complex frequency.<br />

Divides the current measurement by complex frequency.<br />

Uses a reference measurement file taken at speaker terminals to calculate 1m<br />

sensitivity in dBSPL/W. The reference file should have dBV Y units while the one in<br />

memory should be in dBSPL.<br />

Temporally shifts the current measurement by a ms value. Affects phase response.<br />

Merges the current measurement with the part below the selected transition<br />

frequency of a selected compatible file.<br />

Combines the current measurement and the selected file to obtain a constant current<br />

impedance measurement. Both files should be in dBV.<br />

Combines the current measurement and the selected file to obtain a constant<br />

voltage impedance measurement. Both files should be in dBV.<br />

Chapter 11 - Sinusoidal 135