12.3 WATERFALL SPECIFIC CONTROLS<br />

When pressed the waterfall plot is displayed.<br />

When pressed the impulse response loaded in memory is displayed.<br />

Loads an impulse response from disk (from MLS binary files).<br />

Takes current MLS impulse response for waterfall calculation.<br />

Enters the Marker mode (see Fig. 12.5). In this operating mode it is possible to<br />

inspect the single data points of each waterfall slice by clicking and dragging the<br />

mouse.<br />

When in marker mode, moves the selected waterfall slice backwards. The same<br />

action is obtained with the Up-Arrow keyboard shortcut.<br />

When in marker mode, moves the selected waterfall slice frontwards. The same<br />

action is obtained with the Down-Arrow keyboard shortcut.<br />

12.3.1 WATERFALL SETTINGS<br />

Start Frequency<br />

Selects the start frequency for the analysis.<br />

Stop Frequency<br />

Selects the stop frequency for the analysis.<br />

Number of Spectra<br />

Selects the number of data slices to display.<br />

Time Shift (ms)<br />

Selects the time between two consecutive spectra.<br />

Window Rise Time (ms)<br />

Selects the rise time of the data selecting window. Valid only for CSD.<br />

Energy Time Frequency (ETF)<br />

Selects ETF mode waterfalls.<br />

Chapter 12 - Waterfall and Directivity 145