15.5 NOTES ABOUT ACOUSTICAL PARAMETERS MEASUREMENT<br />

This paragraph gives some guidelines that should be followed while executing the<br />

measurement of the impulse response of rooms; what said here should be considered<br />

together the general procedure that is described in chapter 10 for executing MLS<br />

measurements.<br />

The sound source shall be as omni-directional as possible. Maximum acceptable<br />

deviation from omni-directionality should not be higher than ±1dB up to 500Hz, ±3dB<br />

at 1kHz, ±5dB at 2kHz, ±6dB at 4kHz when excited with octave bands noise and<br />

measured in a free field.<br />

Regarding measurement positions it is important to execute an adequate number of<br />

measurements with different source and receiver positions to characterize the entire<br />

room. For large auditoria a number of measurements from 6 to 10 in dependance of<br />

the number of seats (from 500 to 2000) should be carried out.<br />

The microphone should be placed at a height of 1.2m above the floor at audience seat<br />

locations to be representative of listener’s ear height.<br />

Chapter 15 - Acoustical Parameters 183