13.7 THIELE & SMALL PARAMETERS<br />
13.7.1 INTRODUCTION<br />
CLIO handles Thiele and Small Parameters, hereafter referred to as T&S, as a post<br />
process of impedance measurements. Three options are available for source data,<br />
selected by the Data Origin Drop Down Control: Sinusoidal Impedance Data, MLS<br />
Impedance Data, File Data, the last created with either of the previous. There are no<br />
conceptual differences between File and the first two options, beside where the data<br />
resides. Choosing Sinusoidal or MLS, the user should have one of these measurements<br />
in memory while the File Data option will prompt for file selection. Impedance<br />
measurements are therefore the central topic and the previous paragraphs are an<br />
essential background. To get the full set of T&S, two impedance curves are needed. The<br />
first is the loudspeaker’s free air impedance, the second, the impedance obtained either<br />
with Delta Mass or Delta Compliance method. The first consists in adding a suitable<br />
Known Mass to the Loudspeaker cone, the latter in loading the cone with a box of Known<br />
Volume.<br />
13.7.2 T&S PARAMETERS CONTROL PANEL<br />
The User Interface is quite simple with three Buttons, one Drop Down and one Check<br />
Box.<br />
Starts a T&S Parameters procedure. See 13.7.3 for details.<br />
Delta Mass T&S Parameters calculation. See 13.7.3 for details.<br />
Delta Compliance T&S Parameters calculation. See 13.7.3 for details.<br />
The Drop Down allows selecting the data origin as described in the introduction. The LSE<br />
Check Box, when checked, enables a Least Square Error routine while calculating T&S<br />
Parameters; more on this later. Besides information regarding the device tested, the<br />
Control Panel displays 27 parameters. Here is what they are.<br />
168 Chapter 13 - Measuring impedance and T&S parameters