Finally Fig.11.12 shows the distortion analysis carried out with the same microphone<br />

distance as in the past examples and the gating delay set to 1.5ms with the auto delay<br />

option disabled. Fundamental is red, second harmonic (+30dB) blue and third harmonic<br />

(+30dB) green.<br />

120.0<br />

CLIO<br />

180.0<br />

dBSPL<br />

Deg<br />

110.0 108.0<br />

100.0 36.0<br />

90.0 -36.0<br />

80.0 -108.0<br />

70.0 -180.0<br />

10 100 1k Hz<br />

10k 20k<br />

Figure 11.12<br />

142 Chapter 11 - Sinusoidal