16 Leq LEVEL ANALYSIS<br />

16.1 INTRODUCTION<br />

With the Leq Analysis control panel it is possible to execute real-time capture and level<br />

measurement of any kind of signal present at CLIO’s input. The behaviour of the<br />

instrument closely resemble that of a graphical level recorder plus direct-to-disk data<br />

capture.<br />

When analyzing an acoustical event this control panel gives you complete informations<br />

about the equivalent continuous sound level (Leq) and related quantities according to<br />

IEC 61672 standard; if used together the FFT frequency analysis you get a complete<br />

integrating sound level meter.<br />

16.2 THE Leq CONTROL PANEL<br />

Fig. 16.1 The Leq control panel<br />

In Fig. 16.1 you can see the Leq Analysis control panel; this figure shows a low frequency<br />

signal, increased in 2dB steps each maintained for 6 seconds, used for subwoofers<br />

power handling capability. To be noted the equivalent level Leq (black curve), the time<br />

history (red curve), the peak level (blue curve) and the levels with slow and fast<br />

integration (purple and green curves).<br />

For a description of the available shortcuts please refer to section 4.5.2.<br />