The graphs refers to a linearity measurement of a Push Pull tube amp. After processing, the Y scale can be<br />

expanded, still including the whole span, greatly enhancing detail inspection.<br />

14.2.1 TOOLBAR DROP DOWN LIST<br />

Input channel<br />

Selects the input channel configuration<br />

14.2.2 LINEARITY&DISTORTION SETTINGS DIALOG<br />

X Axis Values<br />

Allows setting the X axis extreme left and right values. Has immediate effect, once<br />

OK is pressed, and has only graphical implication; that is it does not affect the actual<br />

or next measure span.<br />

X Axis Unit<br />

Can be either Volts or Watts. Has immediate effect and the curve is recalculated<br />

accordingly. Changing the impedance in the sweep settings does not affect results<br />

as the impedance set at measuring time is taken for calculation. When Vs. input is<br />

selected in the X Axis Vs., Volts is forced and the choice disabled.<br />

X Axis Vs.<br />

Selects if the X axis represents DUT output or input values. Input Values can only be<br />

expressed in Volts.<br />

Y Axis Scale<br />

Selects how the Y axis is displayed. When anything but Linearity is selected in the<br />

Analysis radio button panel, selecting Volts/% will display distortion in percent in<br />

174 Chapter 14 - Linearity & Distortion