Mobile installation procedure<br />

Mobile installation procedure<br />

What you need<br />

This section includes the following topics:<br />

• "What you need" on page 95<br />

• "<strong>AutoVu</strong> SharpX connections" on page 95<br />

In addition to the <strong>AutoVu</strong> parts listed in the section "<strong>AutoVu</strong> hardware components" on<br />

page 4, you will also require the following third-party components:<br />

• 2.5 mm flat head screwdriver. Used for securing wires to the provided connectors.<br />

• RJ45 crimp tool. Used to crimp the CAT5e cable wires.<br />

• Three stranded copper wires. Used to provide power to the LPR Processing Unit. Two<br />

wires should be 14 AWG, and the other should be between 20 AWG minimum to<br />

14 AWG maximum.<br />

• 15A in-line fuse. Protects the wiring to the vehicle battery.<br />

• Weatherproof, non-corrosive sealant. For protecting cable connections.<br />

About third-party connectors<br />

This section describes the connectors that are included with the <strong>AutoVu</strong> SharpX system, but<br />

are not manufactured by <strong>Genetec</strong>.<br />

• Cable connectors are manufactured by Weidmuller. For more information, go to http://<br />

www.weidmueller.com/56339/Home/cw_index.aspx and search for the following part<br />

numbers:<br />

• 1043920000 (3-pole)<br />

• 1690910000 (5-pole)<br />

• 1690880000 (2 -pole)<br />

• The RJ45 connector is manufactured by Tyco Electronics. For more information, go to<br />

http://www.tycoelectronics.com and search for part number 5-569552-3.<br />

For a detailed T568B crimp procedure, click the “Application Specifications” link on the<br />

part’s webpage.<br />

<strong>AutoVu</strong> SharpX connections<br />

This section includes a diagram that shows the supported SharpX connections. Each<br />

connection is labelled A through G, and has specific steps you’ll need to follow. The<br />

remaining topics in this section provide the required information on each connection. For<br />

example, for more information on connection A in the diagram, see "Step A: Provide power<br />

to the LPR Processing Unit (part 1)" on page 98.<br />

genetec.com | <strong>AutoVu</strong> <strong>Handbook</strong> <strong>5.1</strong> <strong>SR2</strong> | Download latest version 95<br />

EN.400.003-V<strong>5.1</strong>.C2(1)