29.10.2014 Views

AutoVu Handbook 5.1 SR2 - Genetec

AutoVu Handbook 5.1 SR2 - Genetec

AutoVu Handbook 5.1 SR2 - Genetec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LED status on the SharpX camera unit<br />

LED status on the SharpX camera unit<br />

The following table describes how the SharpX camera unit’s LED behaves in response to the<br />

SharpX system’s status.<br />

State Description LED (red/green)<br />

Off Unit is powered off Off<br />

Reflash<br />

Get DHCP<br />

The unit has failed an integrity test on<br />

the contents of the control board flash<br />

memory. It waits for a reflash to be<br />

performed over the network.<br />

The unit is waiting for a DHCP lease<br />

over the network (either from the LPR<br />

Processing Unit or an external server,<br />

depending on configuration).<br />

Green (steady)<br />

Blinks green rapidly (e.g. twice per<br />

second).<br />

Normal The camera is running normally. Flashes green briefly every second.<br />

Covert<br />

Thermal<br />

Shutdown<br />

Illuminator<br />

Fault<br />

Firmware<br />

Fault<br />

The camera is configured in covert<br />

mode. It will still blink green a couple<br />

of times at power-up.<br />

The internal temperature is outside<br />

the operational limits. Power is no<br />

longer supplied to most components.<br />

No Ethernet network connectivity is<br />

possible.<br />

An abnormal condition was detected<br />

with the illumination. Depending on<br />

the fault, the unit may run in degraded<br />

mode (some LEDs shut off), or the<br />

illuminator may be completely<br />

disabled.<br />

A critical fault was detected in the<br />

control board microcontroller.<br />

Off<br />

Toggles slowly every second.<br />

Blinks red rapidly (e.g. twice per<br />

second).<br />

Red (steady)<br />

genetec.com | <strong>AutoVu</strong> <strong>Handbook</strong> <strong>5.1</strong> <strong>SR2</strong> | Download latest version 245<br />