Using a SharpX system with multiple LPR Processing Units<br />

Using a SharpX system with multiple LPR Processing Units<br />

If you are using two SharpX LPR Processing Units on the same network (e.g. in the same<br />

vehicle), follow the procedures described in this section to resolve the IP address conflicts<br />

between the units.<br />

This section includes the following topics:<br />

• "About the LPR Processing Unit’s default IP addresses" on page 144<br />

• "Change the LPR Processing Unit’s default IP addresses" on page 145<br />

About the LPR Processing Unit’s default IP addresses<br />

All SharpX LPR Processing Units have seven internal components. Each component has a<br />

factory-assigned static IP address. These components are:<br />

Component<br />

Default IP address<br />

Single Board Computer 1 (SBC1) 192.168.10.1<br />

Single Board Computer 2 (SBC2) 192.168.10.2<br />

<strong>Genetec</strong> Video Processor 1 (GVP1) 192.168.10.3<br />

<strong>Genetec</strong> Video Processor 2 (GVP2) 192.168.10.4<br />

Camera Unit 1 (CAMU1) 192.168.10.5<br />

Camera Unit 2 (CAMU2) 192.168.10.6<br />

Mobile Processing Unit (MPU) 192.168.10.7<br />

Camera Unit 3 (CAMU3) a<br />

192.168.10.8<br />

Camera Unit 4 (CAMU4) 1 192.168.10.9<br />

a. For SharpX – Multi with four camera ports.<br />

If you're using only one LPR Processing Unit on the network (e.g. in a vehicle), you don't<br />

have to change any of the default settings, but if you're using two units on the same network<br />

(sometimes referred to as “daisy-chaining”), the duplicate IP addresses on the units will<br />

conflict. This means you'll need to change the default IP addresses on one of the units. You<br />

can do this using the Sharp Admin.<br />